Advertisement

CSE-947H JBOD Chassis
CSE-947HE1C-R2K05JBOD CSE-947HE2C-R2K05JBOD
USER'S MANUAL
Revision 1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CSE-947H JBOD and is the answer not in the manual?

Questions and answers

Summary of Contents for Supermicro CSE-947H JBOD

  • Page 1 CSE-947H JBOD Chassis CSE-947HE1C-R2K05JBOD CSE-947HE2C-R2K05JBOD USER’S MANUAL Revision 1.0...
  • Page 2 State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
  • Page 3 This document lists compatible parts available when this document was published. Refer to the Supermicro web site for updates on supported parts and configurations. This manual may be periodically updated without notice. Please check the Supermicro Web site for possible updates.(http://www.supermicro.com).
  • Page 4: Table Of Contents

    Chassis CSE-947H JBOD User's Manual Contents Chapter 1 Introduction 1.1 Models ..........................7 1.2 Unpacking the System ......................7 1.3 Chassis Features .........................8 Control Panel ........................8 Chassis Front ........................10 Chassis Rear ........................11 1.4 Where to get Replacement Components ................13 1.5 Returning Merchandise for Service ..................13 Chapter 2 Installation in a Rack 2.1 Preparing for Setup ......................14...
  • Page 5 Preface Opening the HDD Drawer .....................31 3.4 Chassis Components ......................32 Hard Drives ........................32 Hard Drive Carrier Indicators ..................32 Hard Drive Installation ....................33 Expander Modules ......................37 System Cooling .........................39 Checking the Server Air Flow ..................41 Overheating ........................41 Power Supply ........................42 Power Supply LEDs .......................42 Removing the JBOD Control Board ..................43 Appendix A Power Supply Specifications Appendix B Standardized Warning Statements for AC Systems...
  • Page 6 Chassis CSE-947H JBOD User's Manual Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Website: www.supermicro.com Europe Address: Super Micro Computer B.V.
  • Page 7: Chapter 1 Introduction

    Introduction Optimized for enterprise-level high capacity storage applications, Supermicro's CSE-947H JBOD chassis features up to 90 hot-swap 3.5" SAS3 or SATA3 hard drives in top-loading drive bays. It is ideal for cloud backup, data replication, or high density archive storage applications.
  • Page 8: Chassis Features

    Chassis CSE-947H JBOD User's Manual 1.3 Chassis Features Control Panel Power switches and status LEDs are located on the control panel on the front of the chassis. Figure 1-1. Control Panel Location...
  • Page 9 Chapter 1: Introduction Figure 1-2. Control Panel Control Panel Features Item Features Description The main power switch applies or removes primary power from the power supply Power button/ to the server but maintains standby power. To perform most maintenance tasks, unplug the system to remove all power.
  • Page 10: Chassis Front

    Chassis CSE-947H JBOD User's Manual Chassis Front The illustrations below show the features included on the front of the chassis. Secondary HDD Drawer Front Control Panel Release Buttons (on 947HE2C only) Primary Front Control Panel HDD Drawer Lock Screws Enclosure...
  • Page 11: Chassis Rear

    Chapter 1: Introduction Chassis Rear The illustrations below show the features included on the rear of the chassis. Power supply modules display status lights. FAN4 FAN5 FAN6 PSU2 Release Tabs/Node for Secondary Input/Output Module (on 947HE2C only) Release Tabs/Node for Primary Input/Output Module PSU LEDs Node Service Tags...
  • Page 12 Chassis CSE-947H JBOD User's Manual Rear Chassis Features Item Feature Description Power Supply modules Two, redundant hot-swap 2000W titanium-level power supplies Fans Six, hot-swap 80mm high-speed, low vibration cooling fans Mini-SAS Ports Mini-SAS HD ports for internal or external cascading expander combinations...
  • Page 13: Where To Get Replacement Components

    (http://www.supermicro.com/ support/rma/). Whenever possible, repack the chassis in the original Supermicro carton, using the original packaging material. If these are no longer available, be sure to pack the chassis securely, using packaging material to surround the chassis so that it does not shift within the carton and become damaged during shipping.
  • Page 14: Chapter 2 Installation In A Rack

    Chassis CSE-947H JBOD User's Manual Chapter 2 Installation in a Rack This chapter provides advice and instructions for mounting your system in a rack. 2.1 Preparing for Setup The box in which the system was shipped should include the hardware needed to install it into the rack.
  • Page 15: Server Precautions

    Chapter 2 Installation in a Rack • When initially installing the server to a rack, test that the rail locking tabs engage to prevent the server from being overextended. Have a rack lift in place as a precaution in case the test fails.
  • Page 16: Circuit Overloading

    Chassis CSE-947H JBOD User's Manual Circuit Overloading Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
  • Page 17: Installing The Rails

    Chapter 2 Installation in a Rack 2.2 Installing the Rails There are a variety of rack units on the market, which may require a slightly different assembly procedure. Do not use a two-post "telco" type rack. This rail set fits a rack between 27.75" and 38"...
  • Page 18 Chassis CSE-947H JBOD User's Manual 2. Mount the front end of the rail by pushing the outer rail latch through one of the square holes on the front of the rack. 3. Pull the inner rail out of the outer rail until it reaches the rear of the rack.
  • Page 19 Chapter 2 Installation in a Rack 5. Secure the length of the extended rail by tightening the screws into the holes closer to the inner rail. Figure 2-3. Extending the Rail 6. Repeat the preceding steps for the other rail, making sure it is mounted at the same height as the first installed rail so that they are parallel.
  • Page 20 Chassis CSE-947H JBOD User's Manual 7. Secure the rails to the rack by installing screws into the square holes on the front and rear of the rack aligned with the rail holes. Figure 2-5. Securing Rails to a Rack...
  • Page 21: Installing The Chassis Into The Rack

    Chapter 2 Installation in a Rack 2.3 Installing the Chassis into the Rack After the rails are installed on the rack, the chassis can be installed in the rack. It has a net weight of 130lbs and requires two to three people or a lift. Installing the Chassis into a Rack 1.
  • Page 22 Chassis CSE-947H JBOD User's Manual 3. Push the chassis all the way into the rear of the rack until the side brackets on the front of the chassis touch the front of the rack. 4. Secure the front of the chassis to the front of the rack by tightening screws through the chassis bracket holes and the rack holes aligned with them.
  • Page 23: Loading Hdds Into The Chassis On A Rack

    Chapter 2 Installation in a Rack Loading HDDs into the Chassis on a Rack 1. Press the release buttons on both of the front handles downward simultaneously and pull the chassis handles forward from the rack. Release Buttons Figure 2-8. Opening the Chassis on a Rack Stability hazard.
  • Page 24 Chassis CSE-947H JBOD User's Manual 2. Pull open the chassis so that a locking lever on each side of the chassis aligns with the front of the chassis cover and front of the rack, then press the lever down on each side to lock the open part of the chassis in place.
  • Page 25: Chapter 3 Maintenance And Component Installation

    Chapter 3: Maintenance and Component Installation Chapter 3 Maintenance and Component Installation This chapter provides instructions on installing and replacing main system components. To assure compatibility, only use components that match the specifications or part numbers given. Installation or replacement of most components require that power first be removed from the system.
  • Page 26: Cable Connections

    3.2 Cable Connections IPMI The CSE-947H JBOD chassis offers intelligent management with IPMI to provide hardware health monitoring and remote power control. To enable it, connect to the storage enclosure using the dedicated IPMI LAN connector (Figures 1-7 and 1-8).
  • Page 27: Sas Cables

    Chapter 3: Maintenance and Component Installation SAS Cables This drawing shows connectors for SAS cabling for the JBOD. For primary and secondary, the connectors are marked A, B, C, D, E, and F. For the E1C model, SAS cables connect primary receptacles A to F to expander modules B (located between drives 15-29), D (located between drives 45-59), and F (located between drives 75-89).
  • Page 28: Cascading Storage

    Chassis CSE-947H JBOD User's Manual Cascading Storage The following diagram shows a server with a single host bus adapter (HBA). The CSE-947H JBOD storage enclosure model E1C can accommodate this configuration. Server with Single Host Bus Adapter (HBA) External Mini-SAS HD Cable...
  • Page 29 Chapter 3: Maintenance and Component Installation The following diagram shows a server with two host bus adapters (HBAs). The CSE-947H JBOD storage enclosure model E2C can accommodate this configuration. Server with Dual Host Bus Adapter (HBA) External Mini-SAS HD Cable...
  • Page 30 Chassis CSE-947H JBOD User's Manual The following diagram shows two servers with a host bus adapter (HBA) each. The CSE-947H JBOD storage enclosure model E2C can accommodate this configuration. Server with Single Host Bus Adapter (HBA) Server with Single Host Bus Adapter (HBA)
  • Page 31: Accessing The Chassis

    Chapter 3: Maintenance and Component Installation 3.3 Accessing the Chassis Drive bays can be accessed by pulling the HDD drawer forward out of the chassis. Other components can be accessed though the front or rear of the chassis. Caution: Except for short periods of time, do not operate the server without the cover in place.
  • Page 32: Chassis Components

    Chassis CSE-947H JBOD User's Manual 3.4 Chassis Components Hard Drives The CSE-947H JBOD chassis supports 90 3.5" hard drives. They can be removed without powering down the system if your operating system supports RAID. Hard Drive Carrier Indicators Each hard drive carrier has two LED indicators: an activity indicator and a status indicator.
  • Page 33: Hard Drive Installation

    Chapter 3: Maintenance and Component Installation Hard Drive Installation The drives are mounted in drive carriers to simplify their installation and removal from the chassis. These carriers also help promote proper airflow through the drive bays. Removing Hard Drive Carriers from the Chassis 1.
  • Page 34 Chassis CSE-947H JBOD User's Manual Installing a 3.5" Hard Disk Drive With the drive carrier removed from the storage compartment: 1. Under the main the carrier handle, find and then lift the breakout lever and pull out the side of the carrier.
  • Page 35 Chapter 3: Maintenance and Component Installation 2. Remove the dummy drive from the carrier. Figure 3-13. Removing the Drive 3. Insert the hard drive into the drive carrier. Orient the drive by matching the two alignment pins on the side and by noting the notch in the carrier for the HDD connectors.
  • Page 36 Chassis CSE-947H JBOD User's Manual Installing a 2.5" Hard Disk Drive With the drive carrier removed from the storage compartment: 1. Remove the pin from the carrier side and place it in the dummy tray for later use. Figure 3-16. Removing the Carrier Pin 2.
  • Page 37: Expander Modules

    Chapter 3: Maintenance and Component Installation Expander Modules The CSE-947HE1C-R2K05JBOD contains three BPN-SAS3-947EL expander modules, labelled B, D, and F. The CSE-947HE2C-R2K05JBOD contains six BPN-SAS3-947EL expander modules, labelled A, B, C, D, E, and F. Expander A is located between drives 0-14, expander B is located between drives 15-29, expander C is located between drives 30-44, expander D is located between drives 45-59, expander E is located between drives 60-74, and expander F is located between drives 75-89.
  • Page 38 Chassis CSE-947H JBOD User's Manual 2. Lift the unlocked expander module out of the chassis. Figure 3-21. Removing an Expander Module...
  • Page 39: System Cooling

    Chapter 3: Maintenance and Component Installation System Cooling Six hot-swap, heavy-duty rear mounted fans provide cooling. They can be replaced without powering down the system. Fan speed is controlled by a system temperature setting in IPMI. If a fan fails, the remaining fans will ramp up to full speed.
  • Page 40 Chassis CSE-947H JBOD User's Manual Release Tabs Figure 3-23. Removing a Fan or Drive from a Motherboard Sled 4. Place the new fan into the vacant fan bay and confirm that the fan is fully seated in the fan bay.
  • Page 41: Checking The Server Air Flow

    Chapter 3: Maintenance and Component Installation Checking the Server Air Flow • Make sure there are no objects to obstruct airflow in and out of the server. • If you are using a front bezel, make sure the bezel filter is replaced periodically. •...
  • Page 42: Power Supply

    It should be replaced as soon as is convenient. The power supply modules are hot-swappable, meaning they can be changed without powering down the system. New units can be ordered directly from Supermicro or authorized distributors. These power supplies are capable of auto-switching. This feature enables them to automatically sense the input voltage and operate at 100-127V or 230-240V.
  • Page 43: Removing The Jbod Control Board

    If a replacement is necessary, the entire rear node should be replaced. Note: This procedure should only be performed by a qualified technician, in consultation with the Supermicro Technical Support team.
  • Page 44 Chassis CSE-947H JBOD User's Manual 5. Now the JBOD control board and I/O board are visible, installed in a tray. Disconnect all the cables connected on the boards, taking take note of the location for each connector, including the ATX power cable, FAN power cable, IPMI cable, I C cable, and control panel cable.
  • Page 45 Chapter 3: Maintenance and Component Installation 8. Remove the screws securing the I/O board to the tray and lift it out of the tray, disconnecting it from the control board. Figure 3-27. Removing the I/O Board 9. Remove the screws that hold the second tier of the tray in place and lift it off the tray brackets, as shown below.
  • Page 46: Appendix A Power Supply Specifications

    Chassis CSE-947H JBOD User's Manual Appendix A Power Supply Specifications This appendix lists power supply specifications for your chassis system. 2000W (Redundant) MFR Part # PWS-2K05A-1R AC Input 2000W Output @ 230-240V, 10-9.8A, 50-60Hz DC Output +12V/166.7A Power Cord IEC60020 C19 input connector...
  • Page 47: Appendix B Standardized Warning Statements For Ac Systems

    Supermicro's Technical Support department for assistance. Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. These warnings may also be found on our website at http://www.supermicro.com/about/...
  • Page 48 Appendix B: Warning Statements Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
  • Page 49 Appendix B: Warning Statements . ٌ ‫ا ك ً ف حالة و ٌ يك أى تتسبب ف اصابة جسذ ة ٌ هذا الزهز ع ٌ خطز !تحذ ز‬ ‫قبل أى تعول عىل أي هعذات،يك عىل علن بالوخاطز ال ا ٌجوة عي الذوائز‬ ٍ...
  • Page 50 Appendix B: Warning Statements Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación. Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation. .‫יש...
  • Page 51 Appendix B: Warning Statements Warnung Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss- bzw. Überstromschutz installiert ist. Stellen Sie sicher, dass der Nennwert der Schutzvorrichtung nicht mehr als: 250 V, 20 A beträgt. ¡Advertencia! Este equipo utiliza el sistema de protección contra cortocircuitos (o sobrecorrientes) del edificio.
  • Page 52 Appendix B: Warning Statements Power Disconnection Warning Warning! The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components. 電源切断の警告 システムコンポーネントの取り付けまたは取り外しのために、...
  • Page 53 Appendix B: Warning Statements ‫אזהרה מפני ניתוק חשמלי‬ ‫!אזהרה‬ ‫יש לנתק את המערכת מכל מקורות החשמל ויש להסיר את כבל החשמלי מהספק‬ ‫.לפני גישה לחלק הפנימי של המארז לצורך התקנת או הסרת רכיבים‬ ‫يجب فصم اننظاو من جميع مصادر انطاقت وإ ز انت سهك انكهرباء من وحدة امداد‬ ‫انطاقت...
  • Page 54 Appendix B: Warning Statements ¡Advertencia! Solamente el personal calificado debe instalar, reemplazar o utilizar este equipo. Attention Il est vivement recommandé de confier l'installation, le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés. !‫אזהרה‬ .‫צוות מוסמך בלבד רשאי להתקין, להחליף את הציוד או לתת שירות עבור הציוד‬ ‫واملدربيه...
  • Page 55 Appendix B: Warning Statements Warnung Diese Einheit ist zur Installation in Bereichen mit beschränktem Zutritt vorgesehen. Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug, Schloss und Schlüssel oder einer sonstigen Sicherheitsvorkehrung möglich. ¡Advertencia! Esta unidad ha sido diseñada para instalación en áreas de acceso restringido. Sólo puede obtenerse acceso a una de estas áreas mediante la utilización de una herramienta especial, cerradura con llave u otro medio de seguridad.
  • Page 56 Appendix B: Warning Statements Battery Handling Warning! There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions 電池の取り扱い...
  • Page 57 Appendix B: Warning Statements ‫هناك خطر من انفجار يف حالة اسحبذال البطارية بطريقة غري صحيحة فعليل‬ ‫اسحبذال البطارية‬ ‫فقط بنفس النىع أو ما يعادلها مام أوصث به الرشمة املصنعة‬ ‫جخلص من البطاريات املسحعملة وفقا لحعليامت الرشمة الصانعة‬ 경고! 배터리가 올바르게 교체되지 않으면 폭발의 위험이 있습니다. 기존 배터리와 동일하거나 제 조사에서...
  • Page 58 Appendix B: Warning Statements ¡Advertencia! Puede que esta unidad tenga más de una conexión para fuentes de alimentación. Para cortar por completo el suministro de energía, deben desconectarse todas las conexiones. Attention Cette unité peut avoir plus d'une connexion d'alimentation. Pour supprimer toute tension et tout courant électrique de l'unité, toutes les connexions d'alimentation doivent être débranchées.
  • Page 59 Appendix B: Warning Statements Backplane Voltage Warning! Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. バックプレーンの電圧 システムの稼働中は危険な電圧または電力が、 バックプレーン上にかかっています。 修理する際には注意く ださい。 警告 当系统正在进行时,背板上有很危险的电压或能量,进行维修时务必小心。 警告 當系統正在進行時,背板上有危險的電壓或能量,進行維修時務必小心。 Warnung Wenn das System in Betrieb ist, treten auf der Rückwandplatine gefährliche Spannungen oder Energien auf.
  • Page 60 Appendix B: Warning Statements ‫هناك خطز مه التيار الكهزبايئ أوالطاقة املىجىدة عىل اللىحة‬ ‫عندما يكىن النظام يعمل كه حذ ر ا عند خدمة هذا الجهاس‬ 경고! 시스템이 동작 중일 때 후면판 (Backplane)에는 위험한 전압이나 에너지가 발생 합니다. 서비스 작업 시 주의하십시오. Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is.
  • Page 61 Appendix B: Warning Statements ‫תיאום חוקי החשמל הארצי‬ !‫אזהרה‬ .‫התקנת הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬ ‫تركيب املعدات الكهربائية يجب أن ميتثل للقىاويه املحلية والىطىية املتعلقة‬ ‫بالكهرباء‬ 경고! 현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다. Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften.
  • Page 62 Appendix B: Warning Statements Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent. ‫סילוק המוצר‬ !‫אזהרה‬ .‫סילוק סופי של מוצר זה חייב להיות בהתאם להנחיות וחוקי המדינה‬ ‫التخلص...
  • Page 63 Appendix B: Warning Statements Warnung Gefährlich Bewegende Teile. Von den bewegenden Lüfterblätter fern halten. Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt.
  • Page 64 Verbindungskabeln, Stromkabeln und/oder Adapater, die Ihre örtlichen Sicherheitsstandards einhalten. Der Gebrauch von anderen Kabeln und Adapter können Fehlfunktionen oder Feuer verursachen. Die Richtlinien untersagen das Nutzen von UL oder CAS zertifizierten Kabeln (mit UL/CSA gekennzeichnet), an Geräten oder Produkten die nicht mit Supermicro gekennzeichnet sind.
  • Page 65 ‫.قيرح وأ لطع يف ببستي دق ىرخأ تالوحمو تالباك يأ مادختسا .ميلسلا سباقلاو لصوملا مجح‬ ‫ لبق نم ةدمتعملا تالباكلا مادختسا تادعملاو ةيئابرهكلا ةزهجألل ةمالسلا نوناق رظحي‬UL ‫ وأ‬CSA ‫( ةمالع لمحت يتلاو‬UL/CSA) ‫ لبق نم ةددحملاو ةينعملا تاجتنملا ريغ ىرخأ تادعم يأ عم‬Supermicro.
  • Page 66 사항을 준수하여 제공되거나 지정된 연결 혹은 구매 케이블, 전원 케이블 및 AC 어댑터를 사용하십시오. 다른 케이블이나 어댑터를 사용하면 오작동이나 화재가 발생할 수 있습니다. 전기 용품 안전법은 UL 또는 CSA 인증 케이블 (코드에 UL / CSA가 표시된 케이블)을 Supermicro 가 지정한 제품 이외의 전기 장치에 사용하는 것을 금지합니다. Stroomkabel en AC-Adapter...
  • Page 67: Appendix C Backplane Specifications

    The BPN-SAS3-947EB, BPN-SAS3-947EL, BPN-ADP-30SAS3-1/2, and BPN-SAS3-947SB backplanes have been designed to utilize the most up-to-date technology available, providing your system with reliable, high-quality performance. Always refer to the Supermicro website at www.supermicro.com for the latest updates, compatible parts and supported configurations.
  • Page 68 Chassis CSE-947H JBOD User's Manual C.3 Components and LEDs Backplane Connectors and Jumpers Figure C-1. Front Connectors of BPN-SAS3-947EB Figure C-2. Rear Connector of BPN-SAS3-947EB 1. Power Connector: JPWR1. 5. Fault Test Jumper: JP2 (for manufacturer's use only). 2. Adapter Board Connector: J16.
  • Page 69 Appendix C: Backplanes Figure C-4. Front Connectors of BPN-ADP-30SAS3-1 1. Expander Connectors: J1-J6. 3. Backplane Connectors: J7 and J8. 2. SAS Signal Connectors to BPN-SAS3- 947SB Midplane: CN1-CN3. Figure C-5. Front Connectors of BPN-ADP-30SAS3-2 1. Expander Connectors: J1-J6. 3. Backplane Connectors: J7 and J8. 2.
  • Page 70 Chassis CSE-947H JBOD User's Manual Figure C-6. Front Connectors of BPN-SAS3-947SB 9 9 9 Figure C-7. Rear Connectors of BPN-SAS3-947SB 1. Front Panel Power Connector: J43. 6. DIP Switches for Configuring SKU Model: S1 and S2 (for manufacturer's 2. SAS Signal Connectors to Adapter use only).
  • Page 71 Appendix C: Backplanes Backplane LED Indicators LED32 LED35 LED17 LED19 LED21 LED23 LED25 LED27 LED29 LED2 LED8 LED10 LED12 LED14 LED4 LED6 LED30 LED18 LED20 LED22 LED16 LED24 LED26 LED28 LED15 LED3 LED1 LED5 LED7 LED9 LED11 LED13 Figure C-8. Front LEDs of BPN-SAS3-947EB Drive LED Indicators Drive Number HDD Activity LED (blue)
  • Page 72 Chassis CSE-947H JBOD User's Manual LED1 Figure C-9. Front LEDs of BPN-SAS3-947EL BPN-SAS3-947EL LED Indicators Description LED1 Heartbeat LED: A green LED indicates that expander is functioning Status LED: A red LED indicates a fault...
  • Page 73 Appendix C: Backplanes Expander LEDs Figure C-10. Location of BPN-SAS3-947EL LEDs in the Chassis Drive Carrier Handle...
  • Page 74: Appendix D Jbod Control Board

    This manual reflects the most current release of the boards available at the time of publication. Refer to the Supermicro web site at www.supermicro.com for the latest updates, compatible parts, and supported configurations.
  • Page 75 Appendix D: JBOD Control Board General Safety Guidelines • Always disconnect power cables before installing or removing any components from the computer, including the control board. • Disconnect the power cable before installing or removing any cables from the control board. •...
  • Page 76 CSE-947S JBOD User's Manual Figure D-2. Front Connectors of BPN-SAS3-947HEL-JB 1. Mini-SAS HD Ports: J1, J2, and J3. 4. Midplane Connectors: BCN1 and BCN3- BCN6. 2. Fan Connector: FAN1. 3. Manufacturing Test Jumpers: JP1 and JP2 (for manufacturer's use only).
  • Page 77 Appendix D: JBOD Control Board D.4 JBOD Power Up/Power Down Sequences There are several procedures to turn on or off the system with the JBOD control board. Power Up First Use or Power Cord Plug-In 1. Plug the power cords into the rear of the power supplies. 2.
  • Page 78 CSE-947S JBOD User's Manual D.5 Searching for JBOD IPMI IP Address (DHCP) Using SAS in-band (Linux) 1. Identify the JBOD enclosure name, such as /dev/sg4. 2. Use the vpd command to view the JBOD IP address.

This manual is also suitable for: