LG D005KD1N111 Installation Manual page 4

Energy storage system
Hide thumbs Also See for D005KD1N111:
Table of Contents

Advertisement

Available languages

Available languages

Getting Started
4
y If the battery SOC is low the battery may charge from the grid for self-protection. (Emergency
Charging) This function is to prevent shutdown of the ESS, deep discharge and failure of the
Battery Extension Kit. An Emergency Charge is not an ESS fault.
1
NOTE
y Before making connections, please make sure the PV array open circuit voltage is within 800
V. Otherwise the product could be damaged.
y Never use any solvents, abrasives or corrosive materials to clean this product.
y Do not store on or place against any objects to the product. It may cause serious defects or
malfunction.
y Before making a connection, make sure the PV switch on this product is switched off.
y This unit is designed to feed power to the public grid only. Do not connect this unit to an
AC source or generator. Connecting the product to external devices could result in serious
damage to your equipment.
y Serving of batteries should be performed or supervised by LG service person or trained
installer.
y This document is for your reference only. Read the installation manual on the website below.
https://www.lg.com/global/business/ess/residential/dc-5
y Please check the following website for warranty policy.
https://www.lg.com/global/business/ess/residential/dc-5
Indicates a risk of possible damage to the product.

Advertisement

Table of Contents
loading

Table of Contents