Omega i Series User Manual page 41

Temperature/process limit controller
Hide thumbs Also See for i Series:
Table of Contents

Advertisement

INSULATION  
Power  to  Input/Output  
2300  Vac  per  1  min.  test  
1500  Vac  per  1  min.  test  
(Low  Voltage/Power  Option)
Power  to  Relay  Outputs  
2300  Vac  per  1  min.  test
Relay  to  Relay  Outputs  
2300  Vac  per  1  min.  test
GENERAL  
Line  Voltage/Power:  
90  to  240  Vac  +/-­10%,  50  to  400  Hz*  
110  to  375  Vdc,  equivalent  voltage;;4  W
*  No  CE  compliance  above  60  Hz
Low  Voltage/Power  Option:  
12  to  36  Vdc;;  3  W**
External  power  source  must  meet  
Safety  Agency  Approvals.
**  Units  can  be  powered  safely  with  24  Vac  
power  but,  no  Certification  for  CE/UL  are  
claimed.
External  Fuse  Required:  
Time-­Delay,  UL  248-­14  listed:  
100  mA/250  V  
400  mA/250  V  (Low  Voltage/Power  
Option)
Time-­Lag,  IEC  127-­3  recognized:  
100  mA/250  V  
400  mA/250  V  (Low  Voltage/Power  
Option)
Environmental  Conditions:  
0  to  55°C  (32  to  131°F),  
90%  RH  non-­condensing
Protection:  
NEMA-­4x/Type  4x/IP65  front  bezel:  
for  1/16,  1/32  DIN
NEMA-­1/Type  1  front  bezel:  for  1/8  DIN
Approvals    FM,  UL,  C-­UL,  and  
see  CE  Approval  Section
Dimensions    
1/8  DIN:    48  H  x  96  W  x  127  mm  D  
(1.89  x  3.78  x  5")
1/16  DIN:  48  H  x  48  W  x  127  mm  D  
(1.89  x  1.89  x  5")
1/32  DIN:    25.4  H  x  48  W  x  127  mm  D  
(1.0  x  1.89  x  5")
Panel  Cutout:    
1/8  DIN:    45  H  x  92  mm  W    
(1.772"  x  3.622"),  
1/16  DIN:    45  mm  (1.772")  square
1/32  DIN:    22.5  H  x  45  mm  W  
(0.886"  x  1.772")
Weight:    
1/8  DIN  Series:  295  g  (0.65  lb)
1/16  DIN  Series:  159  g  (0.35  lb)
1/32  DIN  Series:  127  g  (0.28  lb)  