→ ALARMING
→ General
→ Buzzer
→ Public door
→ Secure door
BAL_SD_R62_EN_2V2_BLA_121-006454377
→ PAutoReset
→ TTechAlarmDelay
→ TLedIntervall
→ TMatAlarmDelay
→ PEntranceFlash
→ TPubOpenDelayTech
→ TSecOpenDelayTech
→ TTechAlarm
→ TOnTime
→TWrongPos
→ TNotOpNotCl
→ TForcedOpen
→TwrongPos
ON
Selection to switch automatic reset ON or OFF
when alarm is no longer active
(sec)
30
Delay time to active alarming in case of a tech-
nical alarm
(ds)
1
Traffic lights blinking interval during alarm
(sec)
60
Delay time when alarm is from door drives or
faulty sensor
0
Flashing light on the entrance indicates the type
of alarm:
0 = all alarms
1 = intrusion
2 = tailgaiting
3 = technical alarm
4 = sabotage
(ds)
5
Delay time opening public door in case of tech-
nical alarm
(ds)
5
Delay time opening secure door in case of tech-
nical alarm
(min.)
10
Time between repeating signaling with the buzzer
when technical alarm is still active
(ds)
5
Time the buzzer is on
(sec)
30
Delay time alarming public door does not open or
close
(sec)
10
Delay time alarming while public door is between
open and closed position
(ds)
10
Delay time for alarming when the public door is
closed and is no longer sending an opening im-
pulse to the PLC
(sec)
30
Delay time alarming secure door does not open or
close
Parameter overview