Fan Tray Failure - H3C S12500X-2L Installation Manual

Hide thumbs Also See for S12500X-2L:
Table of Contents

Advertisement

1.
Verify that the power supply model is compatible with the switch.
The PSR1800-56A and PSR1800-56D power supplies are compatible with the switch.
2.
Remove and reconnect the power cord to verify that the power cord is connected securely.
3.
Replace the power cord.
4.
Remove and reinstall the power supply to verify that it is installed securely.
For more information, see "Installing power supplies."
5.
Verify that the power source is supplying power at the acceptable voltage range.
6.
Verify that the total maximum output power of all power supplies exceeds the system power
consumption.
7.
Verify that the power supply does not have issues such as output short-circuit, output
over-current, output over-voltage, input under-voltage, or over-temperature.
8.
Install the power supply in another empty power supply slot. If the power supply operates
correctly, the previous power supply slot is faulty. If the power supply does not operate correctly,
go to the next step.
9.
Install a correctly operating power supply of the same model in the same slot, and connect it to
the same power source. If the new power supply can operate correctly, the old power supply
has failed. Contact your sales agent or local service engineer to replace the old power supply.
10. If the issue persists, contact H3C Support.

Fan tray failure

Symptom
The LEDs for the fan tray are in the following states:
On the SEU, the fan tray status LED is steady red.
On the fan tray, the OK LED is off and the FAIL LED is on.
Solution
To resolve the issue:
1.
If all the LEDs are off, verify that the power supplies are operating correctly. For more
information, see
2.
Execute the display fan command in any view to display the operating state of the fan tray and
rectify the fault:
Whether the fan tray is present.
Airflow direction of the fan.
Number of fans in the fan tray.
Operating status of each fan.
Fan speed.
3.
Verify that the air inlet and exhaust vents of the chassis are not blocked. If they are blocked,
clean them to keep good ventilation.
4.
Remove and reinstall the fan tray to make sure it is installed securely in the slot.
5.
Verify that the empty interface module slots and power supply slots are installed with filler
panels. Install filler panels in empty slots.
6.
Replace the fan tray.
7.
If the issue persists, contact H3C Support.
"Power supply
failure."
1-3