5.2.2 HTTP Client

Log in to the web page, in the mode setting menu, select the work role as Station and the service mode as HTTP
Clinet, and save the settings.
(1) Log in to the web page again, and fill in the HTTP server address in the parameter setting menu.
(2) Fill in the HTTP server port number.
(3) The request method can be post or get.
(4) All output is selected as the output mode, the content of the server's reply is all output through the serial port,
and the valid output is selected, and the serial port only outputs valid data.
(5) Enter the URL path of the header.
(6) User-defined input protocol header, if multiple entries need to be added directly\r\ndo not add the last one.
If the user passes parameters via GET, the following explains how to use GET in detail. as follows:
GET /request/login.do?name=test&userpwd=123456 HTTP/1.1
Host: 192.168.4.10:8080
Among them, /request/login.do? is the content set in the header path URL (note that you need to add? After the