Cavius LUMI-PLUGIN LP120 Installation And Specification page 2

Main powered heat alarm downlight

Advertisement

Installation instructions
1) Cut a circular hole in the ceiling (A) 92mm in diameter where
the luminaire is going to be installed. Do not exceed the
cutting diameter. (Diagram 1)
2) Remove the screws on the LED driver(D) and remove end cap.
Take a supply feed from the lighting radial circuit (B). Strip off
the end of the cable (C) and connect to the LED driver (D). Put
the end cap back onto the LED driver (D) and insert screws.
(Diagram 2)
3) Connect the LED Driver output cable to the luminaire. Feed the
mains supply cable (B) and LED driver (D) back through the
92mm cut out hole. (Diagram 3)
4) The heat alarm is held within the luminaire using magnets.
The alarm comes with a cable fitted. Ensure the cable is
coming out of the back of the luminaire and connect to the
mains power.
5) Lift both springs so they are in the upwards position then
insert the luminaire into the 92mm cut out hole in the ceiling.
Make sure no cables are trapped under the springs and that
the luminaire is centred in the hole.
Please note: The alarm is delivered in the packaging with a dust
cover, installed to protect the alarm for exposure to excessive
dust which could potentially damage or reduce the function
of the alarm while the building is under construction. The dust
cover must be removed after the building is fully cleaned.
4
Lumi-Plugin LED Downlight including
spring clips.
LED Driver, complete with mini connector.
Mains Powered Heat Alarm.
4
6 x Screws
2 x Cable Retainer

Advertisement

loading