DROPSA CannonPump User Operating And Maintenance Manual

Electric barrel pump

Advertisement

Quick Links

http://www.dropsa.com
CANNONPUMP
Electric barrel pump
User Operating and
Maintenance Manual
Original text translation
Warranty Information
CONTENT
1.
2.
3.
4.
5.
6.
7.
8.
PROBLEMS AND SOLUTIONS
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
Manual compiled in accordance with Directive
CE 06/42
C2124IE- WK 47/11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CannonPump and is the answer not in the manual?

Questions and answers

Summary of Contents for DROPSA CannonPump

  • Page 1: Table Of Contents

    CANNONPUMP Electric barrel pump User Operating and Maintenance Manual Original text translation Warranty Information CONTENT INTRODUCTION GENERAL DESCRIPTION IDENTIFICATION OF THE MACHINE TECHNICAL FEATURES MACHINE COMPONENTS UNPACKING AND INSTALLATION INSTRUCTIONS FOR USE PROBLEMS AND SOLUTIONS MAINTENANCE PROCEDURES DISPOSAL ORDER INFORMATION...
  • Page 2: Introduction

    DropsA skilled engineers are available to design large scale project and provide installation, commissioning, support and training anywhere in the world. These pumps are supplied without accessories. It is the responsibility of the installer to ensure that the pump is suitable protected with any necessary electrical or mechanical accessory (e.g.
  • Page 3: Identification Of The Machine

    3. IDENTIFICATION OF THE MACHINE On the pump cover there is a product identification label that indicates the part number and characteristic of the pump, including motor voltage. Always ensure you have the correct product for your application. 4. TECHNICAL FEATURES 4.1 ENVIRONMENTAL CONDITIONS grease NLGI 0 -10 °C...
  • Page 4: Machine Components

    5. MACHINE COMPONENTS PUMP COMPONENTS Lifting Lug Outlet Oil lamp Oil drain plug Drum cover Identification Label Follower plate Motor By-pass Oil Fill plug Return Line (plugged) Gearbox reducer Pump Shaft...
  • Page 5: Unpacking And Installation

    6. UNPACKING AND INSTALLATION 6.1 UNPACKING Once a suitable installation position has been identified, unpack the pump and prepare for installation. It is important to inspect the pump to ensure that there has been no damage during transportation. The packaging material used does not require any special disposal procedures.
  • Page 6: Instructions For Use

    WARNING: The machine can be opened and repaired only by Dropsa authorized staff. The following is a diagnostic table showing possible problems, causes and solutions. Having consulted the following table, if problems still exist you should contact a specialized Dropsa technical support point for assistance in resolving any remaining problems.
  • Page 7: Maintenance Procedures

    9. MAINTENANCE PROCEDURES The pumps require only minimal maintenance. To facilitate maintenance it is suggested to install the pump in an easily accessible location (see paragraph 6.2). Periodically check piping joints to detect possible leaks. Periodically check that there is sufficient oil in the gearbox. If necessary top up with ISO VG100 (DIN-51524-2) mineral gear oil.
  • Page 8: Order Information

    230V AC 1Ph – 50Hz – 0.55kW Other spare parts Item Part Number 3301540 24V DC – 0.55kW 0234496 Bypass 3133456 200 kg Drum Lift Kit CANNONPUMP can be customized adding a minimum electric level or a laser probe, for other information contact Dropsa's Technical Office...
  • Page 9: Dimensions

    12. DIMENSIONS ~ 612 DRUM DELIVERY (kg) 20-25 180/200...
  • Page 10: Handling And Transport

    13. HANDLING AND TRANSPORT Prior to shipping, the equipment is carefully packed in cardboard package. During transportation and storage, always maintain the pump the right way up as indicated on the box. On receipt check that package has not been damaged. Then, storage the machine in a dry location.
  • Page 11: Operational Hazards

    The lubricant used during final testing of the unit is a NLGI 2 grease The following is a comparison table between NLGI (National Lubricating Grease Institute) and ASTM (American Society for Testing and Materials) for greases, showing the permissible values for the CannonPump GREASES...
  • Page 12: Warranty

    Dropsa reserves to right to charge an administration fee if the product(s) returned are found to be not defective. This limited warranty does not cover any products, damages or injuries resulting from misuse, neglect, normal expected wear, chemically caused corrosion, improper installation or operation contrary to factory recommendation.
  • Page 13: Declaration Of Compliance

    Besana,5 / Dropsa S.p.A. au Siège Social à Milan, Via Besana,5/ Dropsa S.p.A., Sitz in Milano, Via Besana 5/ La sociedad Dropsa S.p.a., con sede legal en Milán, Via Besana,5/ A Dropsa S.p.A, com sede em Milão, via Besana, nº 5 DICHIARA /CERTIFIES / CERTIFIE/ ZERTIFIZIERT, DASS/ DECLARA/ CERTIFICA: che il prodotto denominato/that the product called/ le produit appelè/ das Produkt mit dem Namen/ el producto que se...
  • Page 14: Distributors

    E-mail: sales@dropsa.it (Export) Fax: (+33) 01 39 86 26 36 E-mail: vendite@dropsa.it (National) E-mail: salesfr@dropsa.com Dropsa (UK) Ltd Dropsa do Brazil Ind. E Com. Ltda Unit 6, Egham Business Village, Rua Sobralia 175, Egham,Surrey,TW20 8RB Sao Paulo, Brazil Tel: (+44) 01784 - 431177...

Table of Contents