Refilling A Canister - Idex Fast & Fluid Management X-SMART Original Manual

Hide thumbs Also See for Fast & Fluid Management X-SMART:
Table of Contents

Advertisement

Operator manual
3.3.5

Refilling a canister

1. In the dispense software, start the fill canister command.
2. Remove the lid (A) from the canister.
3. Follow the instructions on the display.
4. Add the correct colorant (B). Do not spill. Use an X-Smart
paper funnel (C), which is provided in the X-Smart
Maintenance Kit.
5. Place the lid back on the canister.
* X-SMART Maintenance Kit to be purchased separately.
WARNING
Check the material safety data sheet (MSDS) of the colorants for the personal protection measures
that are required for handling the colorant.
CAUTION
Make sure that the colorant level in the canister is correct. If a canister is empty, it can cause an
inaccurate dispensing and/or a recipe fault.
Note
The dispense software checks the level of colorant in each canister. The dispense software shows
when you need to refill a canister.
Note
The fill canister command of the dispense
software controls the motor of the turntable.
The turntable turns the empty canister to the
front.
CAUTION
Do not fill the canister to the brim. Leave at
least 2.5 cm (1 inch) unfilled.
CAUTION
Do not pour the colorant on the agitator.
X-Smart
16
A
B
C
V 1.4