Priming and Pump Speed
Adjustment
NOTE: The reference letters in the following instructions
refer to Typical Installation, page 5.
1. Open the bleed-type master air valve (E).
2. Open the drain valve (M), and slowly open the air
regulator (C) until the pump is running smoothly.
3. After all of the air is purged from the fluid hose,
close the drain valve (M).
4. Use the air regulator (C) to control the pump speed
and fluid pressure. Always use the lowest pressure
necessary to obtain the desired results.
5. The pump will start and stop as the shut-off valve
(N) is opened and closed.
NOTICE
Never allow the pump to run dry of the fluid being
pumped. A dry pump quickly accelerates to a high
speed and may cause damage to the pump seals.
6. If the pump accelerates quickly or is running too
fast, immediately stop the pump by closing the
bleed-type master air valve (E) and check the fluid
supply. If the supply container is empty and air has
been pumped into the lines:
a. Refill the supply container.
b. Prime the pump and fill the lines with fluid to
remove all of the air from the fluid lines.