6.3 Physical Specifications

Table 6-3 Physical specifications
Category
Dimensions (H x W x
D)
Issue 10 (2020-12-15)
Specifications
● The equipment room environment meets the
requirements of ISO 14664-1 Class 8.
● There is no explosive, conductive, magnetic, or
corrosive dust in the equipment room.
NOTE
It is recommended that the particulate pollution in the
equipment room be monitored by a professional agency.
The declared A-weighted sound power levels (LWAd)
and declared average bystander position A-weighted
sound pressure levels (LpAm) listed are measured at
23°C (73.4°F) in accordance with ISO 7779 (ECMA 74)
and reported in accordance with ISO 9296 (ECMA 109).
● Idle:
– LWAd: 6.04 Bels
– LpAm: 46.0 dBA
● Operating:
– LWAd: 6.51 Bels
– LpAm: 50.7 dBA
NOTE
The noise generated during operation varies depending on the
server configuration, load, and ambient temperature.
Description
175 mm x 447 mm x 748 mm (6.89 in. x 17.60 in. x
29.45 in.)