Particle contaminant
Acoustic noise

6.3 Physical Specifications

Table 6-3 Physical specifications
Category
Dimensions (H x W x
D)
Issue 14 (2020-09-03)
Specifications
● The equipment room environment meets the
requirements of ISO 14664-1 Class 8.
● There is no explosive, conductive, magnetic, or
corrosive dust in the equipment room.
NOTE
It is recommended that the particulate pollution in the
equipment room be monitored by a professional agency.
The declared A-weighted sound power levels (LWAd)
and declared average bystander position A-weighted
sound pressure levels (LpAm) listed are measured at
23°C (73.4°F) in accordance with ISO 7779 (ECMA 74)
and reported in accordance with ISO 9296 (ECMA 109).
● Idle:
– LWAd: 5.92 Bels
– LpAm: 42.3 dBA
● Operating:
– LWAd: 6.14 Bels
– LpAm: 46.3 dBA
NOTE
The noise generated during operation varies depending on the
server configuration, load, and ambient temperature.
Description
● Chassis with 3.5" drives: 43 mm x 436 mm x 748
mm (1.69 in. x 17.17 in. x 29.45 in.)
● Chassis with 2.5" drives: 43 mm x 436 mm x 708
mm (1.69 in. x 17.17 in. x 27.87 in.)
Copyright © Huawei Technologies Co., Ltd.