Huawei FusionServer Pro 5288 V5 Manual page 23

Table of Contents

Advertisement

Huawei FusionServer Pro 5288 V5 Server
Technical White Paper
Indicator Description
Table 5-3 Indicators on the rear panel
Indicator
PSU indicator
UID indicator
Connection status
indicator for a GE
electrical port
Data transmission
status indicator for a
GE electrical port
Data transmission
status indicator for
the management
network port
Issue 10 (2020-12-15)
Description
● Off: No power is supplied.
● Blinking green at 1 Hz:
– The input is normal, and the server is standby.
– The input is overvoltage or undervoltage.
– The PSU is in deep hibernation mode.
● Blinking green at 4 Hz: The firmware is being
upgraded online.
● Steady green: The power input and output are
normal.
● Steady orange: The input is normal, but no power
output is supplied.
NOTE
The possible causes of no power output are as follows:
● Power supply overtemperature protection
● Power output overcurrent or short-circuit
● Output overvoltage
● Short-circuit protection
● Device failure (excluding failure of all devices)
The UID indicator helps identify and locate a device.
● Off: The device is not being located.
● Blinking blue: The device has been located and is
differentiated from other devices that have also
been located.
● Steady blue: The device is being located.
NOTE
You can turn on or off the UID indicator by pressing the UID
button or remotely running a command on the iBMC CLI.
● Off: The network port is not connected.
● Steady green: The network port is properly
connected.
● Off: No data is being transmitted on the port.
● Steady yellow: The network port is in active status.
● Blinking yellow: Data is being transmitted.
● Off: No data is being transmitted.
● Blinking yellow: Data is being transmitted.
Copyright © Huawei Technologies Co., Ltd.
5 Hardware Description
16

Advertisement

Table of Contents
loading

This manual is also suitable for:

V100r005

Table of Contents