Resol FlowCon S Installation Operation Commissioning
Resol FlowCon S Installation Operation Commissioning

Resol FlowCon S Installation Operation Commissioning

Solar pump station with integrated controller

Advertisement

Quick Links

F lo w C o n S
Installation
Operation
Commissioning
Manual
Thank you for buying this product.
Read this manual carefully to get the best performance from this unit.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FlowCon S and is the answer not in the manual?

Questions and answers

Summary of Contents for Resol FlowCon S

  • Page 1 F lo w C o n S Installation Operation Commissioning Manual Thank you for buying this product. Read this manual carefully to get the best performance from this unit.
  • Page 2: Table Of Contents

    Safety advice Declaration of conformity Please pay attention to the following safety advice in order We, RESOL Elektronische Regelungen GmbH, D­45527 Hat­ to avoid danger and damage to people and property. tingen, declare under our sole responsibility that our pro­...
  • Page 3: Technical Data And Overview Of Functions

    F lo w C o n S Solar pump station with integrated controller • Integrated D e lt a S o l BS or ® D e lt a S o l BS Plus controller ® • Outstanding design • Safety assembly with relief valve and pressure gauge •...
  • Page 4: Installation

    F lo w C o n S 1. Installation safety head piece with wall mounting fill valve (fill/drain valve) insulation ­ rear part 10 solar pressure gauge 0 ... 6 bar controller 11 solar air vent insulation ­ front part 12 solar safety valve 6 bar flowmeter 13 stainless steel corrugated pipe 3/4"...
  • Page 5: Mounting The Pipes Into A Compression Ring Connection

    F lo w C o n S 1.2 Mounting the pipes into a compression ring connection • First push the union nut (2) then the brass compression Please note: ring (3) onto the copper pipe (1). To guarantee secure In order to absorb the strain of the pipes, corresponding load transmission and sealing, the pipe must extend at fittings (expansion bushings) or more than two 90°...
  • Page 6: Emptying The System

    F lo w C o n S Emptying the system • Open the fill and drain valve at the lowest point of the • Open the non­return valve in the ball valve (see follow­ system, if possible close to the store connection (not ing advice).
  • Page 7 F lo w C o n S Notes:...
  • Page 8 Another use outside the copyright requires best of our knowledge. As errors can never be entire­ the approval of RESOL ­ Elektronische Regelungen GmbH. ly excluded, please note: your own calculations and plans This especially applies for copies, translations, micro films designed to meet current local standards and directives and the storage into electronic systems.