Manual for the
specialised craftsman
Installation
Operation
Commissioning
en
Thank you for buying this RESOL product.
Manual
Please read this manual carefully to get the best performance from this unit.
Please keep this manual carefully.
www.resol.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FlowSol B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Resol FlowSol B

  • Page 1 B / B HE ® Manual for the specialised craftsman Installation Operation Commissioning Thank you for buying this RESOL product. Manual Please read this manual carefully to get the best performance from this unit. Please keep this manual carefully. www.resol.com...
  • Page 2: Table Of Contents

    • Dispose of the packaging in an environmentally DeltaSol BS, DeltaSol C, DeltaSol ® ® ® RESOL. sound manner. Plus or DeltaSol BX series ® • Dispose of old appliances in an environmentally • Safety assembly with connection for the Target group sound manner.
  • Page 3 FlowSol B / B HE ® Pump characteristics / pressure loss characteristics Technical data FlowSol ® B standard pumps Circulating pump: Wilo Star ST 15/6 ECO or 15/7 ECO FlowSol Wilo Stratos TEC 15/6 or 15/1-7; Wilo Yonos Para ® ST 15/7 (HE pumps) Safety valve: 6 bar Pressure gauge: 0 ...
  • Page 4: Mounting The Station

    Note Mounting the station All connections are already tightened such that they usually do not have to be tightened again. However, during commissioning of the system all connections have to be checked for leaks (pressure test). 10 Wall mounting bracket 11 Back half of the insulation 12 Front half of the insulation 13 Hinged controller panel...
  • Page 5: Ball Valve Positions

    Before flushing the system After flushing the system Ball valve positions Î Disconnect the expansion vessel from the solar Î Connect the expansion vessel to the solar ther- Non-return valve in operating thermal system. mal system position, fluid flow in flow direc- Î...
  • Page 6: Flowmeter

    Flowmeter Safety devices The flowmeter measures and indicates the flow rate The pump station is equipped with a diaphragm safety with a range of 1-10 l/min. For the device to function valve which corresponds to the relevant directives faultlessly, the system must be flushed and free of grit. and regulations.
  • Page 7: Accessories

    See our full range of accessories on our website: vessel 28000491 Air separator (not shown) www.resol.com Wall mounting for diaphragm-type expansion vessel 11200071 Wall mounting bracket with screws and wall plugs, high grade steel corru- 70001512 Back half of the insulation Information about the pump gated tube and connection thread ¾".
  • Page 8 - they only represent use outside the copyright requires the approval of RESOL – Elektronische Rege- some examples. They can only be used at your own risk. No liability is assumed for lungen GmbH.