Care For Yourcentral Softener - Ispring WCS45KG Installation Instructions & Operating Manual

Whole house central softener
Table of Contents

Advertisement

If you have not read and truly understood this manual, do not operate this equipment.
The effluent during the regeneration process is not softened, and the water used during the
regeneration of the softener will affect its regeneration effect. It is not recommended to use the
water at this time.
The product can be used frequently after installation and commissioning has been completed. With
an uninterrupted power supply, the user does not need to perform any additional operations on the
machine.
If the equipment fails or experiences other exceptional circumstances, the inlet and outlet valves
can be closed (bypass valve is open), and the municipal water supply can be used directly. After
removal, open the water inlet and outlet valves of the device.
During use of the water softener, do not cut off the power to avoid errors in the clock on the water
softener, which will affect the original regeneration start time and lead to the potential use of
unsoftened water.
Once the water softener has been stopped for a period of time, a regeneration operation should be
added to ensure the quality of the softened water before reuse.
If water consumption increases significantly (relative to normal usage) or the hardness of raw water
increases, the number of regenerations should be increased accordingly. The softening capacity of
the water softener in actual use is not only related to the quality of the raw water but also associated
with the softener's water flow rate. When in use, the flow rate should be appropriately low, which
will better effect water softening.
Hot water will cause severe damage to the water softener's internal system, therefore users who
need to connect a water heater behind the water softener should ensure there is at least a three-
meter tube between the outlet of the water softener and the inlet of the water heater. If the three-
meter connecting pipeline cannot be guaranteed, it is recommended to install a check valve
between the water softener and the hot water heater.
Only silicon-based grease should be used for maintenance. Any other grease formulations will
affect the working life of the water softener.
During regular use of the bypass, do not pull out the clamp. The pressure must be released before
the clamp is removed.
An overflow pipe must be used when installing this product to ensure safe use.
The inlet water temperature of this product is required to be 33.8°F – 102.2°F. The ion exchange
resin loaded in the barrel can easily freeze and crack. Pay attention to freeze prevention to avoid
resin failure.
The product should prevent water hammer effects during operation, such as avoiding rapid full
opening and full closing of valves and emergency stop of water pumps.
Do not apply external force to the device and avoid direct sunlight and radiation from other heat
sources.