CAUTION
DO NOT re-use compressor oil or any oil that has been
exposed to the atmosphere. Dispose of oil per local codes
and regulations. DO NOT leave refrigerant system open to
air any longer than the actual time required to service the
equipment. Seal circuits being serviced and charge with
dry nitrogen to prevent oil contamination when timely
repairs cannot be completed. Failure to follow these proce-
dures may result in damage to equipment. For information
about replacement oil type and viscosity, see the Installa-
tion, Start-Up, and Service Instructions for the 38VMAH
and 38VMAR outdoor units.
UNIT 40VMU
POWER SUPPLY (V-Ph-Hz)
COOLING CAPACITY (Btuh)
HEATING CAPACITY (Btuh)
INDOOR FAN MOTOR
Type
Input (W)
INDOOR COIL
Number of Rows
Fin Spacing (fins/in.)
Fin Type
Tube Diameter, OD (in.)
Tube Type
Number of Circuits
INDOOR AIRFLOW (cfm)
Low
Medium
High
INDOOR NOISE LEVEL (dBA)
Low
Medium
High
UNIT
Unit Dimensions, W x H x D (in.)
Packing Dimensions, W x H x D (in.)
Net/Gross Weight (lb)
REFRIGERANT TYPE
EXPANSION DEVICE
DESIGN PRESSURE, High/Low (psig)
REFRIGERANT PIPING (in.)
Liquid Side, OD
Suction Side, OD
CONNECTING WIRING (AWG)
Power Wiring
Signal Wiring
DRAINAGE WATER PIPE DIAMETER, OD (in.)
LEGEND
AWG — American Wire Gage
EEV
— Electronic Expansion Valve
NEC
— National Electrical Code
The 40VMU under ceiling/floor unit can be installed ex-
posed at the ceiling or mounted on the wall close to the floor. It
is ideal for corner or low-ceiling areas where soffit space is not
available for furred-in units.
The equipment is initially protected under the manufactur-
er's standard warranty; however, the warranty is provided un-
der the condition that the steps outlined in this manual for ini-
tial inspection, proper installation, regular periodic mainte-
nance, and everyday operation of the unit be followed in detail.
This manual should be fully reviewed in advance before initial
installation, start-up and any maintenance. Contact your local
sales representative or the factory with any questions BEFORE
proceeding.
Table 1 lists physical data for each unit size. See Fig. 1 for
the model number nomenclature. Figures 2 and 3 show the unit
dimensions. Table 2 shows components that may or may not be
used for a particular installation.
Table 1 — 40VMU Physical Data
012
015
12,000
15,000
18,000
13,500
17,000
21,000
24
47
2
15
Aluminum with Hydrophilic Coating
3
259
359
294
412
335
441
35.8
41.7
37.7
45.4
40.5
47.2
39 x 26 x 8
1
43 x 29
/
x 12
2
57/71
1
/
4
1
/
2
Sized per NEC and Local Codes Based on Nameplate Electrical Data
2-Core Stranded Shielded Twisted Pair Cable 20 AWG-16 AWG
2

GENERAL

018
024
030
208/230-1-60
24,000
30,000
27,000
34,000
DC Motor
53
80
107
3
14
3
/
8
Copper Tube with Inner Groove
5
394
494
624
424
529
676
471
571
729
44.1
50.2
50.4
46.5
52.0
52.1
48.5
53.8
53.9
1
50
/
x 26
2
x 8
55 x 29
x 12
62/75
77/90
R-410A
EEV (Built-In)
580/320
3
/
8
5
/
8
5
/
8
036
048
36,000
48,000
40,000
54,000
67*2
115*2
7
906
929
976
1000
1094
1353
48.4
50.6
50.3
52.3
53.0
59.8
66 x 27 x 10
1
/
2
75
1
/
x 30 x 13
2
106/128