52

Description

Category 1 definition

IEC/EN 60204-1 defines category 1 emergency stop as a controlled stop with the
power to machine actuators available to achieve the stop and then removal of power
when the stop is achieved.

Implementation of category 1 stop in ACS800 in brief

After the emergency stop command has been given, the drive first decelerates the
motor to a standstill according to a preset ramp time. Then, the line contactor or air
circuit breaker is switched off.

Applicable standards

The emergency stop complies with the following standards:
• IEC/EN 60204-1:1997 "Safety of machinery – Electrical equipment of machines –
Part 1: General requirements"
• EN 418:1992 "Safety of machinery – Emergency stop equipment, functional
aspects – Principles for design"
• EN ISO 12100:2003 "Safety of machinery – Basic concepts, general principles for
design"
• EN 954-1:1996 "Safety of machinery – Safety-related parts of control systems –
Part 1: General principles for design"
• EN ISO 13849-2:2003 "Safety of machinery – Safety-related parts of control
systems – Part 2: Validation".
Category 1 emergency stop for ACS800-07/17/37 (+Q952, R6i, R7i, n×R8i)