4. All lp gas cylinders used with the appliance
must be provided with a shut off valve ter-
minating in a cylinder valve outlet
The cylinder supply system must be arranged
for vapor withdrawal. The cylinder must also
include a collar to protect the cylinder valve.
As well, the cylinder valve must include a safety
relief device having direct communication with
the vapor space of the cylinder.
handling
1. Government regulations prohibit shipping
full lp gas cylinders. You must take your
new cylinder to an lp gas dealer for filling.
2. A filled lp gas cylinder is under very high
pressure.
Always handle with care and
transport in the upright position. Protect
the valve from accidental damage.
3. Do not tip the lp gas cylinder while con-
necting it to the regulator. Fasten the cy-
linder securely during transport, use and
storage.
4. If the cylinder is tipped after it is connected
to the regulator, shut off the gas, discon-
nect the regulator and have it checked be-
fore using it again.
Storage
1. Store the lp gas cylinders outdoors in a
well-ventilated area.
2. Do not store the lp gas cylinders in direct
sunlight or near a source of heat or combu-
stion.
3. If you intend to store your grill indoors,
disconnect and remove the lp gas cylinder
first. Disconnected cylinders must have
plugs installed and must not be stored in
a building, garage or any other enclosed
area.
4. Keep out of reach of small children.
60
5. When the lp gas cylinder is connected to
the gas grill, the lp gas cylinder must be
stored outside in a well-ventilated area.
6. Keep the ventilation openings for the lp cy-
linder enclosure free and clear of debris.
operation
1. Never connect your gas grill to an lp cylin-
der without the regulator provided, and ne-
ver to an unregulated gas supply. The gas
regulator supplied with the appliance must
be used.
2. Always leak test the lp gas cylinder to re-
gulator connection when connecting the lp
gas cylinder to the appliance. See "leak tes-
ting".
3. Do not operate the appliance if the smell of
lp gas is present. Extinguish all flame and
determine the source of lp gas before pro-
ceeding. Do not ignite the appliance until
the lp gas leak has been found and sealed.
4. Always shut off the lp gas cylinder valve
when the appliance is not in use.

connection

1. Be sure the cylinder valve and appliance val-
ves are "off".
2. Place full lp gas cylinder on tank ring brac-
ket.
3. Center the nipple in the cylinder valve and
hold in place. Using the other hand, turn
the hand wheel clockwise until there is a po-
sitive stop. Do not use tools. Hand tighten
only. When making the connection, hold the
regulator in a straight line with the cylinder
valve, so as not to cross thread the con-
nection.
4. Leak test the connection. See "leak test".
5. Refer to lighting instructions. To avoid acti-
vating the flow limiting device when lighting,
open the cylinder valve slowly with the ap-
pliance valves off. If the flow limiting device

Advertisement