Conformity Assessment (Verification) - ELZAB CAT 27 Series User Manual

Calculating electronic scales
Table of Contents

Advertisement

W2:ZERO RANGE EX.
W3:SCALES UNSTABLE
W4:OVERLOADING
W5:UNDERLOADING
W6:TARE RANGE EX.
W7:RS232 PARITY ERR. Wrong transmission parameters of the RS232 interface.
W8:FUNCTION INACCESS Function non accessible at the moment.
W9:WRONG VALUE

8. Conformity assessment (verification)

CAT27 scales are subjected to conformity assessment procedures and meet applicable legal
and metrological requirements, in particular requirements of 2014/31/EU directive. Scale can be
used for commercial transactions where product is sold by weight and for other purposes specified
in the directive.
Confirmation of meeting the above requirements and validity of the conformity assessment
(verification) carried out by the manufacturer are:
 CE marking and supplementary metrology marking on a data plate, consist of the capital
letter 'M' and the last two digits of the year of the conformity assessment, surrounded by
a rectangle
 set of metrological verification stickers, affixed by the manufacturer respect to provided
list.
The value of the gravity coefficient has been adjusted to the designated place of use of the scale.
Using the scale in the different location than the designated place of use may result in the
permissible weighing errors being exceeded.
The user manual contains a declaration of conformity which confirms compliance with
metrological and legal requirements. The declaration of conformity is also available on the
company's web site www.elzab.pl. Copy of the declaration of conformity may be required during
the another periodic legal verification.
In case of damage to the data plate or verification stickers the legal verification and manufacturer's
warranty expire. Further use of the scale for commercial transactions requires legal verification.
Please ask your local authority about national requirements. Re-verification may also be required
after the scale has been repaired or due to other factors that affect the operation of the scale even if
the validity period has not expired.
Periodic legal verification is required after the expiry of the validity period specified in your
national law regulations. The period of validity is calculated from the year of conformity
assessment given on the data plate. Two digits after the metrological marking 'M' indicate the last
two digits of the year in which the conformity assessment was carried out.
The owner of the scale is responsible for the condition of verification and warranty stickers and the
validity of the legal verification.
ELZAB S.A.
Zeroing range exceed when using the key. Decrease the load of
the platter.
Zeroing and taring can't be effected because of unstable load.
The scale load exceeds the maximum scale range.
Decrease the load.
The scale load is less than -20*e
off and on.
The tare can't be inputted because of negative weighing result
or exceeding the maximum range.
Wrong value of entered data.
. Reset the scale or power it
1
User Manual CAT 27 scales series
27