Flint & Walling 50TCPPC Installation Instructions

Advertisement

Quick Links

Notice to Installer: Instructions must remain with installation.
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
These installation instructions are applicable for Model 50TCPPC, ECP552PC, ECP752PC
PRE INSTALLATION CHECKLIST - ALL INSTALLATIONS
1. Inspect your pump. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer
before using. Do Not remove the test plug in the cover.
2. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use.
These materials should be retained for future reference.
SEE BELOW FOR LIST OF WARNINGS
1. To reduce the risk of electric shock, install only a circuit
protected by a ground-fault circuit-interruptor (GFCI). All
pumps are furnished with provisions for proper grounding to
help protect you against the possibility of electrical shock.
2. Make certain that the ground fault receptacle is within the
reach of the pump's power supply cord DO NOT USE AN
EXTENSION CORD. Extension cords that are too long or
too light do not deliver sufficient voltage to the pump motor.
But, more important, they could present a safety hazard if
the insulation were to become damaged or the connection
ends were to fall into the basin and become wet.
3. Make sure the pump electrical supply circuit is equipped
with fuses or circuit breakers of proper capacity. A separate
branch circuit is recommended, sized according the
National Electrical Code for the current shown on the pump
name plate.
4. TESTING FOR GROUND. As a safety measure, each
electrical outlet should be checked for ground using an
Underwriters Laboratory Listed circuit analyzer which will
indicate if the power, neutral and ground wires are correctly
connected to your outlet. If they are not, call a qualified
licensed electrician.
5. Installation and checking of electrical circuits and hardware
should only be performed by a qualified licensed electrician.
6. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP
FROM ITS POWER SOURCE BEFORE HANDLING.
7. These pumps are supplied with a 3-prong grounded plug to
help protect you against the possibility of electrical shock.
DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE
GROUND PIN. The 3-prong plug must be inserted in a
mating 3-prong fault interrupter receptacle. If the installation
does not have such a receptacle, it must be changed to the
proper type, wired, and grounded in accordance with the
National Electrical Code and all applicable local codes and
ordinances.
8. Risk of electric shock. This pump has not been investigated
for use in swimming pool or marine areas.
9. According to the state of California (Prop 65), this product
contains chemicals known to the state of California to cause
cancer and birth defects or other reproductive harm.
Quality Products
Since 1866
INSTALLATION INSTRUCTIONS
© 2019. All rights reserved.
MAIL TO: 95 North Oak Street • Kendallville, IN 46755
(260) 347-1600 • 1 (800) 345-9422 • FAX (260) 347-0909
SEE BELOW FOR LIST OF CAUTIONS
1. Check to be sure your power source is capable of
handling the voltage requirements of the motor, as
indicated on the pump name plate.
2. Vent hole purpose. It is advisable that all submersible
sump pumps be of the bottom intake design to reduce
clogging and seal failures. If a check valve is incorporated
in the installation, a vent hole (approx. 3/16") must
be drilled in the discharge pipe below the check valve
and pit cover to purge the bottom intake unit of trapped
air. Trapped air is caused by agitation and/or a dry
basin. This vent hole should be checked periodically
for clogging. Water stream will be visible from this hole
during pump run periods.
3. Maximum continuous operating water temperature for
standard model pumps must not exceed 104°F (40°C).
Note: Pumps with the "cCSAus" mark are tested to UL Stan-
dard UL778 & CSA Standard C22.2 No. 108.
DO NOT USE FOR PUMPING OILS,
GASOLINE OR ANY PETROLEUM
BY-PRODUCTS.
REFER TO WARRANTY ON PAGE 2.
1
FW1260
0719
Supersedes
1018

Advertisement

loading

Summary of Contents for Flint & Walling 50TCPPC

  • Page 1 INSTALLATION INSTRUCTIONS These installation instructions are applicable for Model 50TCPPC, ECP552PC, ECP752PC PRE INSTALLATION CHECKLIST - ALL INSTALLATIONS 1. Inspect your pump. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using.
  • Page 2 LIMITED WARRANTY This product is warranted for one year from the date of purchase or two years such other place as the manufacturer may designate, freight prepaid. from the date of manufacture, whichever occurs first. Subject to the conditions hereinafter set forth, the manufacturer will repair or replace to the original THE WARRANTY PROVIDED HEREIN IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND MAY NOT BE EXTENDED OR MODIFIED BY ANYONE.