What To Do If - Fujitsu BS2000 SE Series Operating Manual

Server unit x86
Hide thumbs Also See for BS2000 SE Series:
Table of Contents

Advertisement

3 What to do if ...

In this chapter, you will learn how to perform a system dump and create diagnostic documentation for the base
system X2000 when inexplicable system downtime occurs.
In the event of hardware faults the operating system will take the necessary recovery action autonomously.
Customer Service is automatically informed by means of a Service Call and initiates repair measures, possibly in
conjunction with the customer.
The SE Manager displays information on the hardware status of the Server Unit in the menu
Units
tab.
Performing a system dump
Requirement
Logging into the SE Manager as administrator or a privileged operator.
1.
In the menu
Systems -> <se server> (SE<model>) -> <su-name> (SU3xx) -> BS2000
tab (in VM2000 mode the tab must be selected on the monitor VM).
BS2000 Dump IPL
2.
Perform the
The memory dump stored by the DUMP program to disk or tape is required for error diagnosis.
The BS2000/VM2000 system must subsequently be reloaded by means of IPL.
i
Information on SLED operation is provided in the "Introduction to System Administration" manual [ ].
Creating diagnostic documentation
Requirement
Logging into the SE Manager as administrator or a privileged operator.
Hardware -> Units -> <se server> (SE<model>) -> <su-name> (SU3xx) -> Service
1.
In the menu
Diagnostics
tab.
2.
Perform the
Create new diagnostic data
The created diagnostic data file is a compressed tar archive and contains important logging, trace, and
configuration files of the unit. You can download the diagnostic data file and send it to the Support Center for
assessment.
[
action.
[
action.
]
]
Hardware -> Units
,
select the
Operation
8
select the
21

Advertisement

Table of Contents
loading

Table of Contents