Installation and
Operating Instructions
Compressors
Mink MM 1202, 1252, 1322 AP
gas tight
Busch Produktions GmbH
Schauinslandstr. 1
79689 Maulburg
Germany
0870144686 /
201205 / Original instructions / Modifications reserved

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Mink MM 1202 AP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BUSCH Mink MM 1202 AP

  • Page 1 Installation and Operating Instructions Compressors Mink MM 1202, 1252, 1322 AP gas tight Busch Produktions GmbH Schauinslandstr. 1 79689 Maulburg Germany 0870144686 / 201205 / Original instructions / Modifications reserved...
  • Page 2: Table Of Contents

    Technical Data......19 Busch – All over the World in Industry ....20...
  • Page 3: Product Description

    Condensable Vapours). Conveyance of other vapours shall be gases agreed upon with Busch. Conveyance of water or other liquids in Conveying media with a lower or higher density than air leads to an in- liquid phase increases the power consumption and shall therefore creased thermal and/or mechanical load on the compressor and is per- be avoided (risk of drive overload).
  • Page 4: Principle Of Operation

    If anything remains to be ● Make sure that the eyebolts are in faultless condition (replace clarified please contact your Busch representative! damaged, e.g. bent eyebolts with a new ones) ● Make sure that the eyebolts are fully screwed in and tightened by...
  • Page 5: Storage

    VCI-products may attack the surfaces of plastics and elastomers. Seek a clearance of minimum 1 m between the compressor and nearby advice from your local packaging dealer! Busch uses CORTEC walls VCI 126 R film for the overseas packaging of large equipment.
  • Page 6: Gas Inlet

    ● Mount the NEMA-adaptor flange (I) on the motor (the bolts (II) are not part of the Busch scope of delivery) Pressure Connection ● Undo the cylinder screws (VI) and remove the elastomer part (V) ●...
  • Page 7: Connecting Electrically

    Conveying media with a lower or higher density than air leads to an in- creased thermal and/or mechanical load on the compressor and is per- missible only after prior consultation with Busch. Installation and Commissioning MM 1202, 1252, 1322 AP gas tight...
  • Page 8: Conveying Condensable Vapours

    Condensable Vapours). Conveyance of other vapours shall be agreed upon with Busch. Conveyance of water or other liquids in If this is the case, it is necessary to counteract residual condensates liquid phase increases the power consumption and shall therefore by warming up the compressor, conveyance of ambient air after be avoided (risk of drive overload).
  • Page 9: Maintenance Schedule

    ● Remove the eyebolt (g, 615) In case of higher requirements in terms of gas tightness: ● Remove the lid (f, 424) ◆ Replace the shaft seal rings (Busch service) Maintenance MM 1202, 1252, 1322 AP gas tight page 9...
  • Page 10: Every 20000 Operating Hours, At The Latest After 6 Years

    Busch service will only accept compressors that come with a completely filled in and legally binding signed “Declaration of Contamination” CAUTION (form downloadable from www.buschvacuum.com). Pressurised air supply systems supply a too high pressure. Removal from Service Risk of damage to the compressor.
  • Page 11: Troubleshooting

    (t) as required and reassemble Internal parts are worn or damaged Repair the compressor (Busch service) The compressor does not start The drive motor is not supplied with the cor- Supply the drive motor with the correct volt-...
  • Page 12 (the proper function of the fan wheel requires the precise adjustment of the coupling on the motor shaft and on the pump shaft; therefore the motor can be mounted by the Busch ser- vice only) The compressor is blocked Solid foreign matter has entered the...
  • Page 13 Temperature of the inlet gas too high Observe the permitted temperatures for the inlet gas Insufficient gas transfer Provide a pressure relief valve Mains frequency or voltage outside tolerance Provide a more stable power supply range Adjust, repair or replace, respectively In case a pressure relief valve/regulating system is installed: The pressure relief valve/regulating system is...
  • Page 14: Spare Parts

    0-9-414 7782 Fax: 0-9-414 7783 Find the list of Busch companies all over the world (by the time of the publication of these installation and operating instructions) on Ú page 20 (rear cover page). Find the up-to-date list of Busch companies and agencies all over the world on the internet at www.buschvacuum.com.
  • Page 15: Eu Declaration Of Conformity

    EU Declaration of Conformity Note: This Declaration of Conformity and the CE-mark affixed to the nameplate are valid for the machine within the Busch scope of delivery. This Declaration of Conformity is issued under the sole responsibility of the manufacturer.
  • Page 16 blank page MM 1202, 1252, 1322 AP gas tight page 16 0870144686 / 201205...
  • Page 17 blank page MM 1202, 1252, 1322 AP gas tight page 17 0870144686 / 201205...
  • Page 18 blank page MM 1202, 1252, 1322 AP gas tight page 18 0870144686 / 201205...
  • Page 19: Technical Data

    Technical Data For motor connection parameters see nameplate Type ~250 3000 ~255 ... 280 ~280 ... 295 MM 1202 AP ~270 ~280 3600 12.6 ~280 17.3 ~310 ~265 ... 290 3000 ~290 ... 305 ~300 ... 315 MM 1252 AP ~290 12.6 3600...
  • Page 20: Busch - All Over The World In Industry

    Busch – All over the World in Industry www.buschvacuum.com Norway Australia Dr.-Ing. K. Busch GmbH Außenstelle Neuenrade Busch Australia Pty. Ltd. Busch Vakuumteknikk AS Breslauer Str. 36 Hestehagen 2 30 Lakeside Drive 58809 Neuenrade 1440 Drøbak Broadmeadows, Vic. 3047 Tel: (0 23 92) 50 29 92...