TROUBLESHOOTING

Problem
The vacuum cleaner cannot
be switched on.
The full dust container
indicator lights up although it
is not full yet.
Low suction power.
Remote Power not working.
Small electrostatic
discharges occur while
sucking up.
The vacuum cleaner whistles
or vibrates when in use.
The brush moves with diffi-
culty.
The vacuum cleaner switched
off while using
The UV light does not work*
* on some models only
Possible causes / Solutions
Check if the Start/Stop button was pressed.
The plug was not inserted or is not making contact.
If the product is in park position with the Start&Pause function (if
available) remove the brush from housing and press the Start/Stop
button.
Clean the dust container.
Clean the filters and, if needed, replace them.
Make sure the expansion pipe, flexible hose and brush are not
blocked.
Clean the filters and, if needed, replace them.
Make sure the expansion pipe, flexible hose and brush are not
blocked.
Clean the dustbin and its filters.
Check if the level of dust is on the max level, just in case empty the
dustbin.
Battery not charged.
The batteries were positioned incorrectly inside the battery
compartment. Position the two AAA batteries making sure of the
positive and negative poles.
Remove batteries; then position them again, making sure the positive
and negative poles are in the correct position.
Electronic appliances or obstacles may be interfering.
Overheating of the motor. Heavy use can lead to the overheating of
the motor. So wait for 60-90 minutes while the motor cools down (this
depends on physical external parameters).
If very fine dust or powders are sucked up such as flour, etc. small
electrostatic discharges could occur. When sucking up materials
previously mentioned, we advise not to use the metal extension pipe,
but only the plastic flexible hose and to set a low suction power level.
One or more attachments were assembled incorrectly. Make sure the
filters and brushes were assembled according to these instructions.
Clean the filters and, if needed, replace them.
The air regulator is open. Make sure it was closed correctly.
Reduce suction power, especially on carpets and fabrics in general.
Open the air regulator to reduce the "suction effect".
Overheating of the motor. Heavy use can lead to the overheating of
the motor. So wait for 60-90 minutes while the motor cools down (It
depends from physical external parameters).
Make sure the expansion pipe, flexible hose and brush are not
blocked.
Check if the product is placed in the upright position.
If the UV light cover is too dirty, clean with dry cotton cloth
If the UV light is damaged, contact an Authorised Service Center
If the small wheels are blocked, clean and remove the dirt from the
wheels, considering the product unplugged