Kenwood TK-2212 Service Manual page 30

Vhf fm transceiver
Hide thumbs Also See for TK-2212:
Table of Contents

Advertisement

Item
Condition
4.Max deviation TEST CH: Center
Adjust
Low
[Wide]
High
(3 points)
AG:1kHz/150mV
Deviation meter filter
LPF:15kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
5.VOX 1
TEST CH:Center
Writing
AG:1KHz/45mV
6.VOX 10
TEST CH:Center
Writing
AG:1kHz/3.0mV
7.DQT
TEST CH: Center
Balance Adjust
Low
[Wide]
High
(3 points)
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
8.QT Deviation TEST CH: Center
Adjust
Low
[Wide]
High
(3 points)
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH: Center
PTT:ON
9.DQT Deviation TEST CH: Center
Adjust
Low
[Wide]
High
(3 points)
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
10.DTMF Deviation TEST CH:Center
Adjust
LPF:15kHz
[Wide]
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
11.MSK Deviation TEST CH: Center
Adjust
Low
[Wide]
High
(3 points)
LPF:15kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
ADJUSTMENT
Measurement
Test equipment
Terminal
Power meter
ANT
Deviation meter
SP/MIC connector
Oscilloscope
AG
AF VTVM
ANT
TK-2212/2217
Adjustment
Parts
Method
Programming
4.2kHz
Software:KPG-100D (According to
the lager +,–)
2.2kHz
(According to
the lager +,–)
Programming
Make the
Software:KPG-100D demodulation
wave into
square waves
0.75kHz
0.35kHz
0.75kHz
0.35kHz
3.0kHz
1.5kHz
3.1kHz
1.5kHz
Specifications/
Remarks
±80Hz
±80Hz
±40Hz
±40Hz
±40Hz
±40Hz
±100Hz
±100Hz
±100Hz
±100Hz
29