TK-2212/2217
Adjustment Points
AUX
5R
RSSI
BATT+
5C
PCTV
5M
TX-RX unit
Component side
BPF : Band-pass wave form test point
CV : VCO lock voltage adjustment terminal
Common Section
Item
Condition
1.Setting
1) BATT terminal votage:7.5V
2) SSG standard modulation
[Wide] MOD:1kHz,DEV:3kHz
[Narrow] MOD:1kHz,DEV:1.5kHz
2.VCO lock
1) CH:High
voltage
RX
2) CH:Low
3.VCO lock
3) CH:High
voltage
PTT:ON
TX
4) CH:Low
PTT:ON
Transmitter Section
Item
Condition
1.Frequency
1) CH:High
Adjust
2) PTT:ON
2.High power TEST CH: Low
Adjust
BATT terminal voltage:7.5V
PTT:ON
3.Low power TEST CH: Low
Adjust
BATT terminal voltage:7.5V
PTT:ON
28
ADJUSTMENT
BPF
SP–
SP+
B
SB
RXD
TXD
CV
Test equipment
Power meter
DVM
Test equipment
Frequency counter ANT
Power meter
Low'
Ammeter
Center
High'
High
(5 points)
Low'
Center
High'
High
(5 points)
S1
PTT
CN13
ANT
EXT. SP/EXT. MIC
VR1 : Frequency adjustment
TC1 : Transmit VCO lock voltage adjustment
TC2 : Receive VCO lock voltage adjustment
CV : VCO lock voltage adjustment terminal
Measurement
Terminal
ANT
TC2
CV
TC1
Measurement
Terminal
VR1
Programming
Software:KPG-100D
S2
S3
SW1
SW2
TX-RX unit
Foil side
TC1
TC2
J301
CV
Adjustment
Parts
Method
3.8V(TK-2212(K,M) ±0.1V
TK-2217(M))
3.0V(TK-2217(M3))
Check
4.2V(TK-2212(K,M) ±0.1V
TK-2217(M))
2.5V(TK-2217(M3))
Check
Adjustment
Parts
Method
High frequency
±50Hz
5.0W
1.05W
VR1
Specifications/
Remarks
0.6V or more
0.6V or more
Specifications/
Remarks
Note: After replacing
the TCXO(X1) align
frequency.
±0.1W
1.9 A or less
±0.1W
0.9 A or less