Levita AC 12000 Maintenance And User Manual

Levita AC 12000 Maintenance And User Manual

Mobile air conditioning unit

Advertisement

Quick Links

MOBILE AIR CONDITIONING UNIT
LEVITA AC 12000
Maintenance and User's Manual
Caution!
Do not operate the device until you have read the operation and maintenance
manual! Keep this manual for future reference
07/2019 – No. 796A

Advertisement

Table of Contents
loading

Summary of Contents for Levita AC 12000

  • Page 1 MOBILE AIR CONDITIONING UNIT LEVITA AC 12000 Maintenance and User's Manual Caution! Do not operate the device until you have read the operation and maintenance manual! Keep this manual for future reference 07/2019 – No. 796A...
  • Page 2: Table Of Contents

    Thank you for buying this new mobile air conditioning unit. This user manual will help you operate this device in a correct and safe way. We recommend that you take the necessary time to read this manual and understand all the equipment operating functions. Use this equipment only for private use and for the specified purposes.
  • Page 3: Safety Instructions

    SAFETY INSTRUCTIONS This appliance may be used by children aged 8 years or above and by persons with reduced physical, sensory or mental abilities or lack of experience and knowledge if they are supervised or instructed in the safe use of the appliance and understand the possible hazards.
  • Page 4 3. Place the air conditioning unit in a dry place with a flat floor, keeping a minimum distance of 50 cm above the unit and from surrounding objects and walls. 4. After installation, make sure the power cable plug is not damaged and is firmly inserted into the electrical outlet.
  • Page 5 4. Equipment storage: The equipment must be stored according to the manufacturer's instructions. 5. Storage of unpacked (unsold) equipment: The protective packaging for the storage of the equipment must be designed to prevent the coolant leakage if the equipment is mechanically damaged inside the packaging. The maximum allowed number of pieces of equipment stored together is determined by the local regulations.
  • Page 6: Characteristics And Equipment

    PROPERTIES AND ACCESSORIES I/ Properties 1/ All-new appearance, compact design, smooth lines, simple and neat shapes. 2/ The functions include cooling, dehumidifying, ventilation and continuous drainage. 3/ In order to facilitate the installation and smooth flow of hot air through the outlet pipe, the interface with the outdoor environment is located at a suitable height.
  • Page 7: Technical Data

    It must be pulled out to a length of 1.8 Sealing window assembly 排热管组件件 Outlet piping assembly TECHNICAL DATA Levita AC 12000 220 – 240 V ̴ 50 Hz Nominal voltage Cooling power 12000 BTU/hour (3.53 kW) Coolant / Filling weight...
  • Page 8: Operation And Settings

    OPERATION AND SETTINGS Control panel and remote control description 1. Control panel commands Control description: ❶ ❷ ❸ ❹ ❺ ❻ ❼ 1. Timer button 5. Arrow down button 2. Fan speed adjustment button 6. Mode selection button 3. Arrow up button 7.
  • Page 9 • Standby mode (sleep): To switch the air-conditioning unit to the standby mode, push the arrow up button in the cooling mode simultaneously with the fan button until the air-conditioning unit enters the energy-saving and silent mode. After activation of this mode with the air conditioning unit ON and with the Cooling function set up, the pre-set temperature in the room is increased by 1°C after the first hour, then again by 1°C after the next hour, and then the temperature is stabilised at this level.
  • Page 10: Installation And Positioning

    3.2. Overflow protection control: When the water level in the water reservoir exceeds an alarm level, the air conditioning unit gives an acoustic warning signal and the ‘WATER FULL’ indicator starts flashing. In this case, connect the drain hose to the outlet of the air- conditioning unit, put the other end into the waste or a collection container and drain water from the air-conditioning unit (see the Drainage instructions).
  • Page 11 Installation of the window sealing plate assembly parts 1) Partly open the window and fit the window sealing plate assembly into the window (see Fig. 2 and Fig. 3). The plate parts can be placed both in horizontal and vertical positions. 2) Spread the parts of the window sealing plate assembly and adjust the hole distance so that both ends of the plate assembly are in contact with the window frame and attach the assembly parts to the window.
  • Page 12: Drainage Instructions

    Fig. 5 Fig. 6 Important: The length of the outlet piping must be in the range of 280 – 1,500 mm. This length depends on the specification of the air-conditioning unit. Do not use extension pipes or replace original pipes with other ones. This might result in incorrect functioning of the air conditioning unit.
  • Page 13 Notes: 1) Handle the cap and plug with care. 2) When draining water, the air conditioning unit may be tilted slightly backwards. 3) If it is obvious that the container does not take the entire volume of water from the tank, close the drainage hole with a plug to avoid water spilling on the floor or the carpet.
  • Page 14: Maintenance

    MAINTENANCE Cleaning: Before cleaning and maintenance, switch off the air conditioning unit and disconnect the power cable plug from the electrical socket. 1. A/C unit surface Clean with a damp soft cloth. Do not use chemical agents such as benzene, alcohol, petrol, etc., otherwise the surface or the entire air-conditioning unit may be damaged.
  • Page 15: Troubleshooting

    5. Cover the air-conditioning unit with a plastic packaging, place it in a dry place out of reach of children and protect against dust. 6. Remove the batteries from the remote controller and place them in a safe place. Note: Ensure correct storage of the air conditioning unit and all its components in a dry and safe place.
  • Page 16: Equipment Disposal

    EQUIPMENT DISPOSAL Do not dispose of electrical tools into municipal waste! In compliance with European Directive No.: 2012/19/EU, electrical tools must be collected separately and submitted for ecological recycling. Information on the possibilities of disposal of the used equipment can be obtained from the municipal or city administration at your place of residence.
  • Page 17: Ec Declaration Of Conformity

    EC DECLARATION OF CONFORMITY We, Mountfield a.s., Mirošovická 697, 25164 Mnichovice, hereby declare in sole responsibility that the product Mobile air conditioning unit LEVITA AC 12000 (JHS-A018-12KR2/A model) Serial number: 1900001 – 2100000 to which this declaration applies, corresponds to the relevant...