OPTIC REPLACEMENT INSTRUCTIONS

Optic Replacement
Instructions
Warning: DISCONNECT the unit from the electrical power source
before performing any maintenance or cleaning on the Slimline™ Unit.
Caution: Optics contain Mercury. Read and follow the Safety
Information on pages 2 and 3 of this manual when handling the
optics in the Slimline™ unit.
STEP 1: Turn Main Power switch to the "Off" position
STEP 2: Unplug power cord from the electrical receptacle
STEP 3: Using the supplied key, unlock and remove both end panels
STEP 4: Remove optics following these instructions:
Caution: Use clean powde-free latex gloves and eye protection when handling the optics in this unit
• With a firm grip on the upper porcelain end of the optic, use your other hand to grip the optic connector
• Gently 'wiggle' connector while pulling from the optic base
• Gently pull optic from three lamp supports (Do not put any pressure on the side of the optic without support)
STEP 5: Install new optic following these instructions:
• Remove new optic from packaging and gently insert into the three optic clips
• With a firm grip on the upper porcelain end of the optic, use your other hand to grip the optic connector
• Gently connect the optic connector to the optic
Note: Optic connector is keyed with the optic base and will connect in one direction only
• Ensure optic connector and optic base are firmly pressed together
STEP 6: Re-install end panels and lock with the supplied key
STEP 7: Plug power cord back into the electrical receptacle
STEP 8: Test unit for proper operation