SPECIFICATIONS:
Dimensions: 18" x 5.2" x 25"
(457mm x 133mm x 635mm)
Weight: 17.6lbs, 7.9kg
Voltage: 120V @ 60Hz / 220V @ 50/60Hz
Power: 170 Watts (Max)
Control: Speed Control
Mobility: Handle / Stand Brackets
Finish: Black or Beige powder coat
Noise Level: <55dBa
Number of Optics: 1
Air Inlet / Outlet: Louvered panel
Fans & Rating: One 500 CFM
Fan Speed: 200ft³/m
(based on 230VAC, 50Hz fan set on high speed)
Filters: One, 5" x 12.5" x 0.25"
(127mm x 317.5mm x 6.4mm), Washable
Certification: Meets Canada / US – CSA & UL Standards, Meets
CE, REACH, & RoHS, Residual O
GREEN TECHNOLOGY AT WORK
OWNER'S MANUAL
/ Non-accumulative
3
25

Advertisement

loading

Summary of Contents for Odorox Slimline

  • Page 1 • Weight: 17.6lbs, 7.9kg RESIDENTIAL USE. • Voltage: 120V @ 60Hz / 220V @ 50/60Hz • Power: 170 Watts (Max) The SLIMLINE unit is finely tuned to treat ™ • Control: Speed Control bacteria, allergens, viruses, and chemicals • Mobility: Handle / Stand Brackets commonly associated with Sick Building •...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Warning Package Contents Operating the Slimline System Placement Wall Mount Instructions Caring for your Slimline Optic Replacement Instructions Specification and Warranty...
  • Page 3: Warning

    IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. WARNING! Use this hydroxyl generator only for its intended purpose as described in this Owner’s Manual. PLEASE READ AND SAVE examination, electrical or mechanical adjustment, or repair. THESE IMPORTANT SAFETY INSTRUCTIONS • Use generator only for intended use as described in this manual.
  • Page 4: Package Contents

    PACKAGE CONTENTS 1. One Odorox Slimline Hydroxyl Generator 2. Two base brackets 3. Four 8-32 x ¾ inch Phillips (Star) machine screws 4. One 0.05 inch hex key 5. One Owner’s Manual 6. One Warranty Card...
  • Page 5: Operating The Slimline

    The main power for the Slimline can be switched on by turning the rotary switch clockwise. POWER OFF The main power for the Slimline can be switched off by turning the rotary switch counter clockwise to the “OFF” position. FAN SPEED The Slimline is equipped with an air mover fan, which runs between 100 and 400 cubic feet per minute.
  • Page 6: System Placement

    SYSTEM PLACEMENT There are two options available when considering system placement: OPTION ONE: PORTABLE FLOOR STAND The Slimline may be used as a portable, free-standing unit, with the use of the enclosed base brackets (see fig. 1) OPTION TWO: WALL MOUNT...
  • Page 7: Wall Mount Instructions

    4. Please read specification label on product for further information and requirements. PLAN THE INSTALLATION 1. Carefully unpack Slimline and remove from plastic. 2. Remove ON/OFF knob by loosening the two allan (Hex) key set screws using the supplied 0.05...
  • Page 8 WALL MOUNT INSTALLATION 3. Remove four screws on side of unit, then tilt and remove cover. 4. Remove optic reflection plate. 5. Remove lamp optic following these instructions: Caution: Use clean leather gloves and eye protection when handling the optics in this generator •...
  • Page 9 WALL MOUNT INSTALLATION 6. Knock out four pre-punched holes on back panel. 7. If wiring unit from back, knock out pre-punched 7/8 inch hole for electrical connector. If wiring from the side, knock out pre-punched hole on the side of the back panel.
  • Page 10 8. Determine the desired installation location. This location must conform to the Warnings and Cau- tion instructions discussed earlier. This Slimline unit must be anchored securely to a wall or ceiling. The mounting screw locations are designed for standard wood/metal framing with studs on 16 inch centers.
  • Page 11 Secure cover with four screws removed in Step 3. 18. Re-install ON/OFF knob and tighten the two set screws. Do not over-tighten set screws. 19. Turn on electrical service. 20. Turn on Slimline Hydroxyl Generator and set for desired airflow.
  • Page 12: Caring For Your Slimline

    SYSTEM CASE CLEANING Exterior The exterior of the Slimline can be cleaned with mild dishwashing detergent and a clean damp cloth. DO NOT use any all-purpose cleaners with harsh detergents or abrasives, as these may damage the decals and the exterior finish. Care should also be taken to avoid spraying or otherwise directing detergent or water into or around electrical components.
  • Page 13: Specification And Warranty

    Fan Control: Variable Speed Control 100 to 400 cfm LIMITED WARRANTY HGI Industries, Inc. warrants that this Slimline (excluding spare parts and consumables) shall be free from defects in workmanship or materials for a period of one (1) year from the date of purchase.