Smeg PV164CN2AU User Manual page 22

Hide thumbs Also See for PV164CN2AU:
Table of Contents

Advertisement

Burner and nozzle characteristics table
1 ULPG 2.75 kPa
Nominal gas consumption (MJ/h)
Injector (1/100 mm)
Primary air (mm)
2 NG 1.0 kPA
Nominal gas consumption (MJ/h)
Injector (1/100 mm)
Primary air (mm)
Replacing nozzles
1. Unscrew screw A and push air regulator
B as far as it will go.
2. Use a spanner to remove the nozzles C
and install the new ones for the required
gas supply, following the indications
given in the relevant table (see "Burner
and nozzle characteristics table").
The nozzle tightening torque must
be no more than 3 Nm.
24
Installation
AUX
SR
4.1
6.0
54
67
4
2
AUX
SR
4.7
6.1
98
110
4
3
3. Adjust the air flow by moving the air
regulator B to obtain the distance D
given in the relevant table (see "Burner
and nozzle characteristics table").
4. After adjusting each burner, reassemble
the appliance correctly.
RR
R1
9.4
14.5
82
100
2
10
RR
R1
9.4
14.5
135
170
2
6
R2
10.8
85
3
R2
10.8
145
5

Advertisement

Table of Contents