Page 2
• The information in this manual is correct at the time of printing. However, i-SENS reserves the right to make any necessary changes at any time without notice as our policy is one of continuous improvement.
Page 14
Situations Do This • When the control solution bottle was Repeat the not shaken well, control solution • When the meter, test strip, or the control test by referring solution were exposed to high or low to the “Notes” temperatures, on page 21.
Page 19
• During two (2) hours after a meal or exercise • When sick or when glucose levels seem quite lower than test value • When hypoglycemia is not well recognised • When insulin has the biggest effect • During two (2) hours after an insulin injection www.i-sens.com 35...
If the sample drop of blood runs or spreads due to contact Note: Please contact your authorised i-SENS sales with hair or with a line in your palm, do not use that sample. representative, if such messages are displayed even though Try puncturing again in a smoother area.
Target Blood Glucose Ranges Meter Memory The NoCoding1 Plus meter can save up to 1,000 glucose test Reminders Your target ranges results with time and date. If the memory is full, the oldest test from your healthcare professional Time of day result will be deleted and the latest test result will be stored.
Page 22
Press the ▲ button to button ▲ view 1, 7, 14, 30 and Fasting 90-day average values average and the number of tests (1, 7, 14, 30, performed fastings with 90 days) symbol for the last test period. button ▼ 40 www.i-sens.com www.i-sens.com 41...
Setting the Alarm Function Viewing Test Results Stored in the Memory Four types of alarms can be set in the NoCoding1 Plus Meter: one post-meal alarm (PP2 alarm) and three time set alarms Step 1 (alarm1-3). The PP2 alarm goes off 2 hours after setting the Press any button to turn the meter on.
Page 24
Press the ● button for 3 seconds to finish Press the ▲ button to adjust the time of and turn the meter off. ‘alarm1’ . A number indicating the hour will blink on the screen. Press the ▼ button to set the hour. 44 www.i-sens.com www.i-sens.com 45...
The blood or control solution sample was > Do not use the meter. Contact your applied before the symbol appeared. authorised i-SENS sales representative. > Repeat the test with a new test strip and wait until the symbol appears before applying the blood or control solution sample.
System has been evaluated in laboratory and in clinical tests. • Check whether the test strip is Accuracy: The accuracy of the NoCoding1 Plus BGM System inserted with the contact bars facing (Model GM01BAA) was assessed by comparing blood glucose up.
Page 27
Interferent Precision: The precision studies were performed in a laboratory 50-100 mg/dL 250-350 mg/dL (2.8-5.5 mmol/L) (13.9-19.4 mmol/L) using NoCoding1 Plus BGM Systems. Acetaminophen -2.3 mg/dL (-0.1 mmo/L) -3.3% Within Run Precision *Bloodav 36 mg/dL (2.0 mmol/L) SD = 2.9 mg/dL (0.2 mmo/L) Ascorbic acid 7.3 mg/dL (0.4 mmol/L)
Warranty Information Manufacturer’s Warranty Difference Averages i-SENS, Inc. warrants that the NoCoding1 Plus Meter shall be Interval 1 Interval 2 Interferent free of defects in material and workmanship in normal use for 50-100 mg/dL 250-350 mg/dL a period of five (5) years. The meter must have been subjected (2.8-5.5 mmol/L)
Need help?
Do you have a question about the NoCoding1 Plus and is the answer not in the manual?
Questions and answers