Advertisement

Visit the webpage below to
see supported devices/
download app (scan the QR
code for easy access).
www.i-sens.com/smartlog
i-SENS, Inc.
43, Banpo-daero 28-gil, Seocho-gu,
Seoul 06646, Korea
© 2019 i-SENS, Inc. All Rights Reserved. PGM7E0212 REV1 2019/04
Medical Technology Promedt
Consulting GmbH,
Altenhofstrasse 80,
66386 St. Ingbert, Germany

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Nipro Premier alpha and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for i-SENS Nipro Premier alpha

  • Page 1 (scan the QR code for easy access). www.i-sens.com/smartlog i-SENS, Inc. Medical Technology Promedt 43, Banpo-daero 28-gil, Seocho-gu, Consulting GmbH, Altenhofstrasse 80, Seoul 06646, Korea 66386 St. Ingbert, Germany © 2019 i-SENS, Inc. All Rights Reserved. PGM7E0212 REV1 2019/04...
  • Page 2: Bluetooth Wireless Technology

    The Nipro Premier alpha Meter is designed to work with the SmartLog™ mobile app. When using the Nipro Premier alpha System, we suggest you pair your Nipro Premier alpha Meter with your smartphone and track your results.
  • Page 3 Trademarks The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by i-SENS, Inc. is under license. All other trademarks and trade names are those of their respective owners. Note: The SmartLog mobile app may not be compatible with all smartphones.
  • Page 4 Nipro Premier alpha Blood Glucose Monitoring System - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -...
  • Page 5 Fresh • Y our Nipro Premier Blood Glucose Test Strip must be used venous whole blood drawn by healthcare professionals can with Nipro Premier alpha Blood Glucose Meter. Do not use be used also. Nipro Premier alpha Blood Glucose Monitoring with other blood glucose meters.
  • Page 6: Specifications

    Specifications Nipro Premier alpha Blood Glucose Monitoring System Product specification Nipro Premier alpha System includes the following items: Measurement range 1.1–33.3 mmol/L * Nipro Premier alpha Blood Glucose Meter Sample size Minimum 0.4 μL * Owner's Booklet Test time 5 seconds...
  • Page 7: Inserting Or Replacing The Batteries

    Inserting or Replacing the Batteries Caring for Your System The Nipro Premier alpha meter uses two 3.0 V lithium batteries. Use a soft cloth or tissue to wipe the meter exterior. If necessary, Before using the meter, check the battery compartment and dip the soft cloth or tissue in a small amount of alcohol.
  • Page 8: Confirmation Window

    Warning! • Y our Nipro Premier Blood Glucose Test Strip must be used with Nipro Premier alpha Blood Glucose Meter. Do not use Caution: with other blood glucose meters. • K eep the meter and testing supplies away from young children.
  • Page 9 Nipro Premier alpha Meter Nipro Premier alpha Meter Display Test results : test results displaying panel Data Port Button ● Memory recall mode : appears when Used to transfer data Turns the meter test results stored in the memory are...
  • Page 10: Setting Up Your System

    Setting Up Your System Setting Up Bluetooth Press and hold the ● button for 3 seconds to enter SET mode. After all settings are finished, press and hold the ● button for 3 Step 2 Bluetooth Pairing seconds to turn off the meter. If you do not want to connect your meter Press the ◀...
  • Page 11 Nipro, may be incompatible with your meter. Premier XXXX) on the SmartLog Visit www.i-sens.com/smartlog for more information about mobile app screen. supported smartphones. You can also scan the QR code on the The meter will display six digit back cover of this user manual.
  • Page 12: Adjusting The Date And Time

    Adjusting the Date and Time Step 7 Setting the Time Format Step 4 Setting the Year The meter can be set in the AM/PM 12-hour or the 24-hour clock format. Press the ◀ or ▶ button to adjust until the Press the ◀...
  • Page 13: Setting The Sound On/Off

    Setting the Sound On/OFF Turning on the Strip Expiration Date Indicator Step 10 Step 11 On pressing the ◀ or ▶ button, the This setting allows you to turn the strip expiration date indicator screen will display 'On' or 'OFF' . Press the on or off.
  • Page 14: Setting The Strip Expiration Date Indicator

    Setting the Strip Expiration Date Indicator Setting the Hypoglycemia (HYPo) Indicator Step 1 Entering the Expiration Date Setting Step 12 Press and hold the ◀ and ▶ buttons at the same time for 3 This setting allows you to turn the hypoglycemia indicator seconds to enter the expiration date settings.
  • Page 15: Checking The System

    Checking the System You may do a control solution test: You may check your meter and test strips using the • W hen you want to practice the test procedure using the control Nipro Premier Control Solution. solution instead of blood, The Nipro Premier Control Solution contains a • W hen using the meter for the first time, known amount of glucose and is used to check that • W henever you open a new vial or a new box of test strips, the meter and the test strips are working properly.
  • Page 16 Step 4 Waiting for the Result Step 3 Applying Control Solution to Test Strip The display segments will rotate Shake the bottle before each test. clockwise and a test result will Remove the cap and squeeze the bottle to appear after the meter counts discard the first drop.
  • Page 17: Using The Lancing Device

    Using the Lancing Device Comparing the Control Solution Test Results You will need a lancing device in order to collect a blood sample. The test result of each control solution should be within the You may use the lancing device that is included in the Nipro range printed on the label of the test strip vial.
  • Page 18: Preparing The Lancing Device

    Preparing the Lancing Device Step 5 Step 1 The lancing device has seven puncture depth settings, numbered 0 through 5 Wash hands and sample site with (0 for a shallow puncture, 5 for a deeper soap and warm water. Rinse and dry puncture).
  • Page 19: Blood Glucose Testing

    Blood Glucose Testing Preparing the Meter and Test Strip Step 9 After the symbol appears on the screen, apply the Step 7 blood sample to the narrow end of the test strip till the meter Insert a test strip with beeps.
  • Page 20 Step 10 Step 11 At this time, the display segments will rotate clockwise while the You can attach a flag to a blood glucose test result to indicate blood is going in. particular situations while the strip is still in the meter. When Test result will appear after the meter counts down from 5 to 1.
  • Page 21: Alternate Site Testing

    Alternate Site Testing Discarding Used Lancets What is AST (Alternate Site Testing)? Step 1 Usually, we take the blood sample from the tip of the finger. However, since there are many nerve endings in the fingertip, it Unscrew the lancing device tip. can be quite painful.
  • Page 22 Things to Know When Using AST AST Precautions Please read the following before testing at alternate sites • B efore using AST, please consult your healthcare (forearms and palms). professional. The capillary whole blood of the fingertips reflects changes in • D o not ignore the symptoms of hyperglycemia or glucose levels more rapidly than in alternate sites. The test results hypoglycemia.
  • Page 23: Hi And Lo Messages

    Supplement 1, S13-S27) immediately. Transferring Test Results Test results stored in Nipro Premier alpha meter can be transferred from the meter to a computer using SmartLog software and cable. The meter Note: screen displays 'Pc' when it is connected to Please contact your authorised Nipro sales representative if the computer using the data cable.
  • Page 24: Meter Memory

    Meter Memory The Nipro Premier alpha meter can save up to 1,000 test results Step 3 Viewing Pre-meal Averages with time and date. If the memory is full, the oldest test result button Repeatedly press the ◀ ◀ will be deleted and the latest test result will be stored.
  • Page 25 Viewing Test Results Stored in Memory Step 6 Step 1 Use the ▶ button to scroll back through the averages seen Press any button to turn the meter on. The current previously. date and time will be displayed on the bottom of Press the ●...
  • Page 26: Setting The Alarm Function

    Setting the Alarm Function Step 2 Turning the PP2 alarm OFF Four types of alarms can be set in the Nipro Premier alpha To turn off the PP2 alarm, press Meter: one post-meal alarm (PP2 alarm) and three time set and hold the ◀...
  • Page 27: Setting The Time Alarms (Alarm 1-3)

    Setting the Time Alarms (alarm 1–3) Step 4 Step 1 On pressing the ◀ button, the number Without inserting a test strip, press the ◀ indicating the minute will start blinking. and ● buttons simultaneously for 3 seconds Press the ▶ button to set the minute. to enter the time alarm setting.
  • Page 28: Understanding Error Messages

    Understanding Error Messages A used test strip was inserted. This error message may appear when the > Repeat the test with a new test strip. wrong blood glucose test strip is used instead of the Nipro Premier test strip. > Repeat the test with a Nipro Premier test strip.
  • Page 29: General Troubleshooting

    Monitoring System has been evaluated in laboratory and in clinical tests. • C heck whether the test strip is Accuracy: The accuracy of the Nipro Premier alpha BGM System inserted with the contact bars facing (Model GM01IAB) was assessed by comparing blood glucose upwards.
  • Page 30 599/600 (99.8%) Interferent Interval 1 Interval 2 Precision: The precision studies were performed in a laboratory 2.8–5.5 mmol/L 13.9–19.4 mmol/L using Nipro Premier alpha BGM Systems. Within Run Precision Ascorbic acid -0.1 mmol/L 0.0 % *Bloodav 2.1 mmol/L SD = 0.1 mmol/L Bilirubin 0.1 mmol/L...
  • Page 31 User Performance Evaluation Difference Averages A study evaluating glucose values from fingertip capillary blood Interferent Interval 1 Interval 2 samples obtained by 100 lay persons showed the following 2.8–5.5 mmol/L 13.9–19.4 mmol/L results: Dopamine 0.02 mmol/L -0.3 % 100% within ± 0.83 mmol/L of the medical laboratory values at glucose concentrations below 5.55 mmol/L, and 100% within Gentisic acid 0.04 mmol/L...
  • Page 32: Warranty Information

    Warranty Information Manufacturer’s Warranty MEMO Nipro warrants that the Nipro Premier alpha Meter shall be free of defects in material and workmanship in normal use for a period of five (5) years. The meter must have been subjected to normal use. The warranty does not cover improper handling, tampering, use, or service of the meter.