Specifications ---------------------------------------------------------------------------------- TEE2 Blood Glucose Monitoring System---------------------------------------------- Inserting or Replacing the Batteries ----------------------------------------------------- Caring for Your System ---------------------------------------------------------------------- TEE2 Blood Glucose Test Strip ---------------------------------------------------------- TEE2 Blood Glucose Meter --------------------------------------------------------------- TEE2 Blood Glucose Meter Display ------------------------------------------------------- Preparation Setting up Your System --------------------------------------------------------------------...
Page 3
* The information in this manual is correct at the time of printing. However, i-SENS reserves the right to make any necessary changes at any time without notice as our policy is one of continuous improvement.
TEE2 Blood Glucose Monitoring System should be used only for function. self-testing outside the body (in vitro diagnostic use only). A TEE2 • T he TEE2 Blood Glucose Meter should be used only with the Blood Glucose Monitoring System should not be used for the TEE2 Strip.
Inserting or Replacing the Batteries Caring for Your System The TEE2 Meter comes with two 3.0 V lithium batteries. Use a soft cloth or tissue to wipe the meter exterior. If necessary, Before using the meter, check the battery compartment and the soft cloth or tissue might be dipped in a small amount of insert batteries if empty.
TEE2 Blood Glucose Test Strip The TEE2 blood glucose monitoring system measures Warning! blood glucose quickly and accurately. It automatically absorbs • T he TEE2 Test Strip should be used only with fresh capillary the small blood sample applied to the narrow edge of the strip. whole blood samples.
• The cable for data management software can be ordered Note: It is recommended to check if the display screen on the separately. Please contact your authorised i-SENS sales meter matches the illustration above every time the meter representative. turns on. Do not use the meter if the display screen does not • T he unit of measurement is fixed and it cannot be changed...
After setting the year, press the displayed in the 24-hour format. M button to confirm your selection and After selecting the format, press the M progress to setting the month. button to progress to setting the hour. 14 www.i-sens.com www.spirit-healthcare.co.uk 15...
• A t any stage, if the M button is pressed for 3 seconds, Time and Date setting mode will finish and the meter will be turned off. Press and hold C to scroll through numbers quickly. 16 www.i-sens.com www.spirit-healthcare.co.uk 17...
19-20. symbol will be displayed on the screen. Notes: • U se only the TEE2 Control Solution (available for purchase separately). Step 2 • C heck the expiration dates printed on the bottle. When you first Shake the TEE2 Control Solution open a control solution bottle, record the discard date (date bottle before each test.
Caution: opened plus three (3) months), bottle of control • T he range printed on the test strip vial is for the TEE2 • W hen the control solution is solution. Control Solution only. It does not have any connection to contaminated.
Using the Lancing Device You will need a lancing device in order to collect a blood sample. Preparing the Lancing Device You may use the lancing device contained in the TEE2 Blood Step 1 Glucose Monitoring System or any other medically approved lancing device.
Step 5 Marking Post-meal Test Results To cock the lancing device, hold the The TEE2 meter allows you to mark a result of a post-meal test body of lancing device in one hand. Pull with symbol. The post-meal test mark ( ) can be attached the sliding barrel with the other hand.
Er4 message may appear. It is recommended that the application of blood sample to the test strip be performed virtually vertical to the sample site as shown in the diagram below. Good Sample Insufficient Sample 26 www.i-sens.com www.spirit-healthcare.co.uk 27...
Then press the release button while continuing to apply lancet. Always dispose of lancets properly. pressure. Keep holding the lancing device against your skin until sufficient (at least 0.5 μL, actual size: ) blood is drawn. Carefully lift the lancing device away from your skin. 28 www.i-sens.com www.spirit-healthcare.co.uk 29...
Page 17
• I f the sample drop of blood runs or spreads due to contact • When insulin has the biggest effect with hair or with a line in your palm, do not use that sample. • Two (2) hours after an insulin injection Try puncturing again in a smoother area. 30 www.i-sens.com www.spirit-healthcare.co.uk 31...
Diabetes – 2012. ” Diabetes Care. January 2012; 35(1):S11-S63. Note: • P lease contact the Spirit Healthcare 24/7 Freephone Support Line at 0800 881 5423 or go to www.spirit-healthcare.co.uk, if such messages are displayed even if you do not have hyperglycaemia or hypoglycaemia. 32 www.i-sens.com www.spirit-healthcare.co.uk 33...
Transferring Test Results Meter Memory The TEE2 Meter can save up to 500 glucose test results with Test results stored in TEE2 meter can be time and date. If the memory is full, the oldest test result will be transferred from the meter to a computer deleted and the latest test result will be stored.
Page 20
Step 5 Pre-meal Use the M button to scroll back through the averages seen average previously. Press the M button for 3 seconds to turn the meter off. (1, 7, 14, 30, 90 days) M button 36 www.i-sens.com www.spirit-healthcare.co.uk 37...
'alarm' operating range. range (5-50˚C/41- symbol being displayed. 'alarm' disappears 122˚F) and repeat the test after the meter and test strips have reached a temperature within the operating range. 38 www.i-sens.com www.spirit-healthcare.co.uk 39...
• C heck whether the batteries are This error message Repeat test after inserted with the ‘+’ side facing up. may appear when inserting a TEE2 test • Replace the batteries. the wrong blood strip. glucose test strip is used instead of TEE2 The test does not • C heck if the confirmation window is...
Performance Characteristics Precision: The precision studies were performed in a laboratory The performance of TEE2 Blood Glucose Monitoring System has been evaluated in laboratory and in clinical tests. using TEE2 BGM Systems. Accuracy: The accuracy of the TEE2 BGM System (Model Within Run Precision GM505KAB, GM505KBB) was assessed by comparing blood Blood avg.
Warranty Information MEMO i-SENS,Inc. warrants that the TEE2 Meter shall be free of defects in material and workmanship in normal use for a period of five (5) years. The meter must have been subjected to normal use. The warranty does not cover improper handling, tampering, use, or service of the meter.