product replacement

how to replace an ingredient cartridge

Remove cartridge and tray from dispenser and separate cartridge
from plastic tray and recycle the outer paperboard box.
Remove the empty ingredient cartridge from
the plastic tray. And clean tray with dish soap,
followed by approved sanitizer solution (Kay-5).
Using the cartridge slot cleaning tool (part
#149324), clean the cartridge slot area. Dip a
clean cloth in approved sanitizer solution, wipe
the probes (that insert into cartridges), then dip
a new clean cloth into the sanitizer solution and
wipe the probes again to sanitize.
Open new cartridge using perforated cartridge
opening flap.
Remove (outer) white dust-cap prior to placing
cartridge into plastic tray.
Be aware of the alert.
A light appears in the
top right corner to
signify an ingredient
cartridge is empty.
10
| © 2020 The Coca-Cola Company | Coca-Cola Freestyle® 9000 User Guide | Confidential information of The Coca-Cola Company | 20200820
Always place ingredient cartridge into plastic
tray and ensure plastic fitment from cartridge
pouch aligns with tray.
Ensure the ingredient cartridge is aligned with
the slot found on the plastic tray.
Remove foil safety seal prior to inserting into the
dispenser.
Insert cartridge and close the cartridge slot
door.
Close the dispenser lower door and follow
on-screen instructions to complete the cartridge
prime process (instructions on page 9).
Reminder Always replace any
missing or damaged cartridge
doors or plastic trays
immediately to prevent dispensing
issues. Replacement doors and
plastic trays can be ordered by
calling 1-800-241-COKE (2655)