• The by-pass hose must have an inner diameter equal to the outer diameter of the by-pass connec-
tion, it has to withstand a pressure of 10 bar (145 psi) and have no throttlings.
• The outlet hoses must have an inner diameter equal to the outer diameter of the outlet connections
and withstand a pressure at least equal to the control unit one.
• For the hydraulic connections, please refer to the following chart and to the example shown on
Fig. 4. The numbers in brackets relate to Figs.1 and 2.
a
Tank
b
Suction filter
c
Suction circuit
d
Pump
e
Pressure circuit
a) Connect the outlet of the pump to the inlet connection (1).
b) Connect the by-pass connection (4) to the tank, paying attention to avoid throttlings.
c) Connect the outlet connections (3) to the relevant devices.
CAUTION
f
By-pass circuit
g
Spraying gun (example of use)
h
Spraying booms (example of use)
i
Control unit