• The control unit is sensitive to frost.
To prevent icing inside the control unit in cold climates, it is suggested to suck an automotive anti-
frost liquid (dilute as per indications on product label) and then completely dump the circuit, for
instance by running the pump for some minutes without sucking any liquid.
• The anti-frost liquid must be duly disposed and not dispersed in the environment.
6. m
aintenanCe
Before starting any maintenance operation make sure that the spraying machine is not working and
that there is no liquid under pressure in the circuits
6.1 o
m
rdinary
aintenanCe
Follow what indicated in the chart below.
ChECKING PERIOd
After every usage
Every 50 working hours
• During the operation, the control unit must not show any leakage. If this happens, have the unit be
checked by a Skilled technician.
• To clean the control unit do not use thinners or solvents.
20
CAUTION
CAUTION
carry out a cleaning cycle by letting water
circulate
Grease rotating and sliding parts
Verify control unit fixing points on the spraying
machine.
If the assembling is insecure, do not use the
machine and concact a skilled technician