Safety State Diagram - 0N3 X5 System User Manual

Table of Contents

Advertisement

3.4 Safety State Diagram

This paragraph provides a description of Safety State Machine for the X5 System, including one Wireless Handheld
and one Base Station. For both devices the States are:
OFF
The device is switched OFF
IDLE
The device is switched ON, the status is UNPAIRED
RUN
The device is switched ON, the status is PAIRED
SAFE
The device is switched ON, the status is UNPAIRED
SAFE - P
The device is switched ON, the status is PAIRED
EMG
The device is switched ON, the status is PAIRED
The transition among Safety States are defined by the following Events:
OFF
Switch OFF
ON
Switch ON
PAIR
Pairing procedure (Wireless Handheld)
UNPAIR
Unpairing procedure (Wireless Handheld)
AUX-REC
Auxiliary unpairing Input (Base Station)
LINK-LOSS Loss of Wi-Fi Link
LINK-REC
Recovery of Wi-Fi Link
PAIR-LOSS* Loss of PAIRED Status
FAIL
System Failure
*Note: PAIR-LOSS can be caused by a device fault or hardware reset when the device is in RUN or SAFE-P States
MANUGENX5 - Version 1.01 24.03.2021
© 2021 0N3 s.r.l. - Subject to change without notice