  • Page 1 Getting Started 26/04/2016...
  • Page 2: Table Of Contents

    Table of Content KUNBUS GmbH Table of Content 1 Introduction ............................. 3 1.1 Getting Started .......................... 3 1.2 FNL............................ 3 2 Install.............................. 4 2.1 Install FNL .......................... 4 2.2 Install Software .......................... 4 3 Ethernet............................ 5 3.1 Set TCP/IP-Adresse ......................... 5 3.2 Set operation mode ........................ 7 4 PROFIBUS............................ 10 4.1 Master............................ 10...
  • Page 3: Introduction

    This manual describes the operation- and configuration options oft the KUNBUS-FNL. The practical examples illustrate the most common applications to facilitate first use of the KUNBUS FNL. 1.2 FNL FNL is an Ethernet based PROFIBUS-DP-Gateway which supports DP Master as well as DP Slave mode. FNL can be directly operated via its TCP/IP Socket.
  • Page 4: Install

    2 Install 2.1 Install FNL Install FNL according to the Installation Instructions (document FNL_EN.pdf), by connecting FNL to a power supply (24 Volts DC) as well as to an Ethernet network. The A PC used for the FNL configuration must be connected to the same Ethernet network as well.
  • Page 5: Ethernet

    3 Ethernet 3.1 Set TCP/IP-Adresse Start the program "KUNBUS Network Configurator" from the Windows Start Menu "KUNBUS GmbH/Network Configurator". The KUNBUS Network Configurator scans automatically the network and displays all detected FNL devices: – For scanning the network again, click the "search"-symbol on top-left.
  • Page 6 – Double click the FNL to be configured and adjust the IP address, Subnet mask and Gateway. Using DHCP to obtain the IP address automatically is possible as well. Illustration 2: Adjustment of the TCP/IP-address 6 / 22 FNL Getting Started...
  • Page 7: Set Operation Mode

    FNL-Mode FNL supports 2 operation modes to guarantee the downwards compatibility to existing applications. – Select the tab Advanced and adjust the parameter FNL-Mode to "KUNBUS interface": Illustration 3: Adjustment of the FNL operation mode FNL Getting Started 7 / 22...
  • Page 8 I/O configuration set by the PROFIBUS DP Master. Illustration 4: FNL DPAutoSlaveMode This option is only available from firmware version 2.19.14. Please contact KUNBUS support if you need to update the firmware. 8 / 22 FNL Getting Started...
  • Page 9 – Click the OK button to close the "device properties" dialogue box. "Network Configurator" activates the changed parameters on the related FNL device and displays it: Illustration 5: Abbildung 5: FNL with changed parameters – Close the "Network Configurator" FNL Getting Started 9 / 22...
  • Page 10: Profibus

    4 PROFIBUS 4.1 Master PROFIBUS DP configuration (Configurator II) The PROFIBUS configuration is performed with the tool "KUNBUS Configurator II". "Configurator II" is a powerful tool to create PROFIBUS configurations, download and test online. After creation and download of the PROFIBUS configuration you can test it immediately with "monitor/modify"...
  • Page 11 PROFIBUS DP configuration download CONFIGURATOR II provides an integrated download function to flash the PROFIBUS DP Configuration on the FNL device. Proceed the following steps: – Select Driver Selection from the Online Menu: Illustration 7: Driver selection The installed FNL devices are displayed: Illustration 8: Installed FNL device Select a FNL device and click the OK button.
  • Page 12 Illustration 9: Download symbol The PROFIBUS DP configuration is downloaded to the FNL device: Illustration 10: Download of PROFIBUS configuration Monitor/Modify-Mode With the "Configurator II" Monitor/Modify mode the flashed PROFIBUS DP configuration can be tested immediately. Please note that the configured DP Slaves must be connected to the FNL. –...
  • Page 13 "Configurator II" displays the online status of the DP-slaves: Illustration 12: Monitor/Modify mode "Configurator II" displays the status of every DP Slave (coloured frame) and allows to monitor and modify the I/O data, and also display the PROFIBUS specific diagnostic-data by clicking the DP Slaves.
  • Page 14 – Display of diagnostic information The sample program is located in the directory"program files \KUNBUS GmbH\FNL\Sample code\Basic DP Master Socket Example\". The project can be directly loaded and compiled with Microsoft Visual C++ 6.0. The sample program is a 32 Bit console application focussing on the FNL programming interface.
  • Page 15 – Enter the number of the FNL to be used. Illustration 15: Sample program: FNL reset – Press a key to reset FNL. Illustration 16: Sample program: Start cyclic profibus traffic – Press a key to start cyclic profibus traffic. Illustration 17: Sample program: Get current profibus configuration –...
  • Page 16 Illustration 18: Sample program: Get the slave diagnostic information – Press a key twice get the slave diagnostic information. Illustration 19: Sample program: start watchdog monitoring – Press a key twice to start watchdog monitoring. Illustration 20: Sample program: Profibus Profibus exchange data –...
  • Page 17 Illustration 21: Sample program: Reset FNL – Press a key to reset FNL. Illustration 22: Sample program: Exit sample program – Press a key to exit sample program. FNL Getting Started 17 / 22...
  • Page 18 Detailed Profibus-DPV1 information can be found in the provided manual "DP_DPV1_E.pdf". The sample program is located in the directory"program files \KUNBUS GmbH\FNL\Sample code\CS_Profibus_Demo\". The project can be directly loaded and compiled with Microsoft Visual C+ + 6.0. The sample program is a 32 Bit console application focussing on the FNL programming interface.
  • Page 19 – After the selection of "Search and list all TCP Devices" (Key 9), enter the number of the FNL to be used. Illustration 24: Sample program: Scope of operation Selection of the needed functions. The DPV1-functions can be found from point 50 to 54. Detailed Profibus-DPV1 information can be found in the provided manual "DP_DPV1_E.pdf".
  • Page 20: Slave

    – •Read/Write of IO data The sample program is located in the directory "program files \KUNBUS GmbH\FNL\Sample code\Basic DP Auto Slave Socket Example\". The project can be directly loaded and compiled with Microsoft Visual C++ 6.0 and it is a 32 Bit console application focussing on the FNL programming interface.
  • Page 21 Illustration 26: Sample program: Display of connected FNL devices – Enter the number of the FNL to be used. Illustration 27: Sample program: FNL reset – Press a key to reset FNL. Illustration 28: Profibus exchange data – Press a key successively to start the profibus exchange data. In the sample program you can exchange data 10 times at most.
  • Page 22 Illustration 29: Sample program: FNL reset – Press a key to reset FNL. Illustration 30: A Sample program: Exit Sample program – Press a key to exit sample program. 22 / 22 FNL Getting Started...