User Manual
KUNBUS-FNL
PR1011081 • 25/04/2016

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FNL Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kunbus FNL Series

  • Page 1 User Manual KUNBUS-FNL PR1011081 • 25/04/2016...
  • Page 2: Table Of Contents

    Table of content KUNBUS GmbH Table of content 1 Working with FNL.......................... 3 1.1 Disclaimer.......................... 3 1.2 User ............................ 4 1.3 Symbols............................. 4 1.4 Safe Use............................ 5 1.5 Limitation of Liability ........................ 5 1.6 Customer Service ........................ 6 2 Overview ............................ 7 2.1 FNL............................ 7 2.2 PROFIBUS DP .......................... 8 2.3 PROFIBUS PA .......................... 9...
  • Page 3: Working With Fnl

    © 2016 KUNBUS GmbH, Denkendorf (Deutschland) The contents of this user manual have been prepared by the KUNBUS GmbH with the utmost care. Due to the technical development, the KUNBUS GmbH reserves the right to change or replace the contents of this user manual without prior notice. You can always obtain the latest version of the user manual at our homepage: www.kunbus.de...
  • Page 4: User

    1.2 User The Gateway may only be assembled, installed and put into operation by trained, qualified personnel. Before assembly, it is absolutely essential that this documentation has been read carefully and understood. Expertise in the following fields is assumed: – Electronic circuits, –...
  • Page 5: Safe Use

    Ø Please note that the warranty shall become invalid if the products are changed technically. èSpeak to your contact person at the KUNBUS GmbH about customised solutions. 1.5 Limitation of Liability Warranty and liability claims will lapse if: –...
  • Page 6: Customer Service

    1.6 Customer Service If you have any questions or suggestions concerning this product, please do not hesitate to contact us: KUNBUS GmbH Heerweg 15 C 73770 Denkendorf Germany +49 (0)711 3409 7077 support@kunbus.com www.kunbus.com 6 / 31...
  • Page 7: Overview

    2 Overview 2.1 FNL The present document shall describe the hardware installation of the FNL module and its corresponding interfaces i.e. interface modules. FNL is a gateway between IP-based Ethernet networks (10/100 Mbit/s) and the field bus PROFIBUS DP. 7 / 31...
  • Page 8: Profibus Dp

    2.2 PROFIBUS DP FNL supports PROFIBUS DP (RS485 bus) up to 12 Mbit/s The current configuration is indicated on the side label of the FNL. Illustration 1: FNL DP RS232 service interface [} 16] Ethernet socket 10/100 RJ45 [} 12] 24 V supply voltage [} 11] LEDs [} 17] PROFIBUS socket RS485 [} 13] 8 / 31...
  • Page 9: Profibus Pa

    2.3 PROFIBUS PA FNL supports PROFIBUS PA (IEC1158-2 bus) with 31.25 Kbit/s. The current configuration is indicated on the side label of the FNL. FNL is not intrinsic save. To connect FNL to intrinsic save PROFIBUS PA networks intrinsic save barriers must be used. Illustration 2: FNL PROFIBUS-PA/31.25 KBit/s Service-Interface RS232 and 24 V output for PA power supply [} 16] PROFIBUS-PA socket [} 14]...
  • Page 10: Install

    3 Install 3.1 Assembly The FNL module is designed for hat rail assembly according to DIN 50022. ◦ Take the device out of the box and hold it upright so that the letters are legible. ◦ Now, position the recess for the rail right above the hat rail and press the device downwards until it snaps in.
  • Page 11: Connect Power Supply

    3.2 Connect Power Supply The power supply basis for the FNL module is 24 V DC. The following options for a correct connection exist: 0 V is to be connected either to clamp 9 or 10 whereas +24 V to clamp 11 or 12.
  • Page 12: Connect Ethernet

    3.3 Connect Ethernet The Ethernet 10/100 baseTX is to be connected to the front part of the RJ45 connector. To do so, insert the corresponding plug until it snaps in. The shield is connected to the hat rail. Please note that the transmission rate adjusts itself automatically: the slowest rate on the network determines the speed.
  • Page 13: Connect Profibus Dp Rs485

    3.4 Connect PROFIBUS DP RS485 NOTICE! The following section is intended for product variant PR 10110801. The PROFIBUS DP is connected to the front side of the module on the 9-pin DSUB, as depicted in Figure 3: Connections and Plugs FNL with PROFIBUS DP/12 Mbit/s.
  • Page 14: Connect Profibus Pa

    3.5 Connect PROFIBUS PA NOTICE! The following section is intended for product variant PR 1011085. The PROFIBUS PA (IEC1158-2) is accessible via clamps 13, 14, 15, 16, which are to be combined in one plug which is coded for the sake of an unmistakable assignment.
  • Page 15 Illustration 5: Connection PROFIBUSS PA 1 Connection to RS232 interface 2 Connection to PROFIBUS PA (IEC1158-2) 15 / 31...
  • Page 16: Connect Service Interface

    3.6 Connect Service Interface RS232 Service Interface To configure the FNL, terminals can be connected via the terminal connection (RS232/V24). In general, the terminal consists of a PC with corresponding terminal emulation. We recommend hyper terminal under Windows XX. What can be controlled or observed via the terminal is described in the section „Setting into Operation“.
  • Page 17: Signals And Fault Indication

    4 Signals and fault indication 4.1 LEDs The LEDs depicted above have the following meaning: bus failing, red, lighting whenever the PROFIBUS is not yet con- figured or cannot be operated Run* bus running, green, lighting while the PROFIBUS is in operation. receiving, green, lighting while the FNL is receiving data on the Eth- ernet transmitting, green, lighting while the FNL is sending data on the...
  • Page 18: Configure Fnl

    5 Configure FNL 5.1 Software Installalation KUNBUS and TMG i-tec offer different software packages for the FNL: – KUNBUS Network Configurator Tool Basic tool for FNL Network configuration – KUNBUS OPC Server for Windows NT/2000/XP/7 Data Access 2.0 OPC Server incl. configuration tool and OPC test client –...
  • Page 19: Configure Fnl

    5.2 Configure FNL Configuration of the FNL TCP/IP Address Double click the appropriate FNL in the displayed list and enter the TCP/IP Address, Subnet mask und Gateway. – TCP/IP-Address – SubNet-Mask – Gateway Illustration 7: Set TCP/IP-Address 19 / 31...
  • Page 20 FNL versions. Illustration 8: Set operation mode KUNBUS Interface The operation mode KUNBUS interface is to be configured for the use of FNL in combination with the following applications: – KUNBUS TCP/IP-Socket-based programming interface – MODBUS TCP Server Interface –...
  • Page 21 The operation mode TMG interface ensures the downwards compatibility to previous FNL versions and is to be used with the following applications: – TMG i-tec DPE-programming interface – KUNBUS FNL OPC-Server – KUNBUS FDT comDTM Illustration 9: Configure FNL-operation mode (TMG Interface) 21 / 31...
  • Page 22 If the operation mode TMG interface is selected and if a FNL symbolic name and Timeout are already configured, they are additionally displayed in the General Tab Illustration 10: Configure TCP/IP Adresse and Timeout (TMG Interface) 22 / 31...
  • Page 23 DPAutoslaveAddress. FNL will detect the PROFIBUS Baud rate automatically and accepts the I/O configuration set by the PROFIBUS DP Master. Illustration 11: FNL DPAutoSlaveMode This option is only available from firmware version 2.19.14. Please contact KUNBUS support if you need to update the firmware. 23 / 31...
  • Page 24 The following chapters. are only necessary for the operation with OPC Server or DPE Programming Interface. To use FNL with the DPE programming interface or the KUNBUS OPC Server a symbolic name and a timeout value must be assigned to the FNL. This can be performed by the TMG Setup program (TMGDEVICES.exe) within scope of delivery:...
  • Page 25 Name declaration for a FNL with TMG Setup Normally the PC application communicates with the FNL with its IP address via a TCP/IP connection. A problem could occur, if the TIP- address has to be changed for any reason With the help of the TMG Net Series-interface the FNL can be approach with its symbolic name.
  • Page 26 Configuration of a new FNL – If you wish to add a new FNL, click onto the Add button. The following window will appear: Illustration 13: Property dialog – Select the type FNL from the list box Board Type: Illustration 14: Select Board Type 26 / 31...
  • Page 27 FNL's – In the field IP Address, enter the TCP/IP address of the FNL. The IP address must match with that assigned by the KUNBUS Network Configurator Tool. Otherwise the DPE Programming Interface or the OPC Server cannot communicate with the FNL via the symbolic name.
  • Page 28 Changing an already configured FNL Click onto the name of the FNL you wish to change. The command button Properties will be activated. Click onto it. The following window will appear: Illustration 16: FNL Properties The symbolic name, the TCP/IP address and the Timeout value can be changed.
  • Page 29: Disposal

    6 Disposal 6.1 Dismantling ü Remove the mains plug of the FNL from the power supply ü Remove the field bus plugs. ◦ Remove the notch at the lower bar with a screwdriver. ◦ Lift up the FNL and remove it. ð...
  • Page 30: Technical Data

    7 Technical Data 7.1 Technical Data G61740x Dimensions 114,5 mm x 99 mm x 45 mm Environmental temperature during 0 … 40 °C operation Environmental temperature during -40 ... 100 °C storage Safety EN60950 Electromagnetic compatibility EN50081-2 und EN50082-2 (EMV) FNL NET+ARM-Modul B617401 Processor...
  • Page 31 FNL PA-Modul B617403 PROFIBUS IC Find 1, alternatively SPC4-2 bus interface IEC1158-2 or DIN EN 61158-2 Current consumption without bus 50 mA at 24 V (supplied by NET+ARM supply module) Type of PROFIBUS PA bus supply Internal or external Supply voltage for internal PA bus 18 …...