TROUBLESHOOTING GUIDE

The troubleshooting and the eventual checks must be performed by qualified personnel only.
The technician that services the machine must wear hearing and eye protection while servicing the dryer.
Each employee must select a proper personal protection device (PPD) hearing protector such as
earmuffs, ear canal caps or earplugs in order to prevent permanent hearing damage or loss.
SYSTEM
TROUBLE
 No power
❖ Dryer stopped
 Valve problem
 No pilot control air
 Solenoid valves
 Controller
 Compressor off
❖ All the inlet air is
 Faulty inlet valve
 Faulty signal
discharged
through the
silencers
 Faulty Outlet valve
 Pneumatic
 High dew point
❖ Liquid comes out
 Overloaded
of the silencers
 No power
❖ Depressurization
 Flow control valve
 No pilot control air
 Exhaust Silencers
DRYPOINT XFi 1000 manual_revA EN
POSSIBLE CAUSE
Order No.
1500
4040827
4034811
4034796
2
4034837
On Request
2
On Request
On Request
SUGGESTED ACTION
 Check power and electric
 Check the operation of inlet and purge exhaust valves
 Ensure Control pilot air is delivering at 80 psi
 Ensure DIN connectors are properly attached to solenoid
valves
 See controller troubleshooting
 Check if compressor Sync is commanding dryer off
 The inlet valves are blocked – open and clean
 The controller continuously supplies solenoid valve PVA
and/or PVB – check the electric wiring and if necessary
replace
 Outlet Check valve(s) stuck open – serviceable only by
qualified technician
 Ensure tube routing matches diagram
 Ensure operation sequence and purge setting
 Check capacity versus operating conditions
 Check purge exhaust valve for normal operation
 Ensure that the purge exhaust valve actuators is not
closed
 Ensure pilot air reading is 80 psi
 Replace silencer filter elements if clogged