Purge Valve Adjustment
The purge flow control valve must be set according to the inlet pressure of the dryer. The valve must be opened to the
corresponding number of turns referenced in the table below.
Always base the pressure adjustment on the lowest operating pressure of the system
The procedure for adjusting the purge flow control valve is as follows:
Rendered drawing of purge
flow control valve
The purge control valve should be set during initial installation & setup and then not adjusted further unless the
operating pressure changes or other problems arise.
1. Begin by fully closing the valve. Rotate the knob clockwise until rotation stops.
2. If no reference mark exists, use a permanent marker to make two aligned markings on the valve stem
and valve body indicating the closed position.
3. Referencing a calibrated flow meter, rotate the knob counter clockwise in 1/8 turn (45 degree)
increments until the desired flow rate has been achieved, counting each time a full rotation has been
made.
4. Record the standard system pressure and valve setting in this manual for future reference. A blank
table has been provided below for this purpose.
5. At a minimum, the purge control valve must allow enough airflow to fully repressurize the dryer during
the 4 minuet repressurization phase. This should be verified using the lowest observe system dryer
inlet pressure.
Purge Adjustment Table
Purge Flow
Rate [scfm]
Dryer
XFi 800
131
XFi 1000
164
XFi 1200
196
XFi 1500
246
XFi 1800
295
XFi 2300
376
XFi 2800
458
XFi 3300
540
XFi 4000
655
XFi 5000
818
XFi 6000
982
Consult a factory representative for more information.
DRYPOINT XFi 1000 manual_revA EN
Turn knob clockwise
(to the right) to close
Model:
_________________
Serial Number:
_________________
Inlet Pressure:
_________________
Purge Rate:
_________________
Purge Valve Setting: _________________
Turn knob counter clockwise
(to the left) to open
18

Advertisement

Table of Contents
loading

Table of Contents