5.5.7
Valve Position Indicators (Standard)
Valve position indicators are mounted on the inlet and regeneration exhaust valves of the dryer. These provide a visual
indication of the valve state (open or closed) and an electrical signal into the dryer's BEKOTOUCH 2 controller. If the
valve is detected in the improper state based on the sequence step, the dryer will alarm.
5.5.8
Filter Contamination (Optional)
Filter Contamination is detected for either the Pre or Post filter by using the CLEARPOINT® pressure differential gauge
along with electrical contacts. When the pressure differential across the element is too great an electrical signal is
generated to the PLC providing a minor alarm message to change the media or check for trouble.
5.5.9
Drain Alarm (Standard)
Drain Alarm is a feature that is provided for customers by utilizing the BEKOMAT drain alarm features. The BEKOMAT is
able to flag the PLC and indicate a contaminated status, in trouble or simply reached its service interval. The drain thus
provides a signal to the PLC generating a minor alarm to notify the customer of the date and time of the event.
5.6

Electrical Wiring Diagram

Please see suplimentarty manual for electircal drawings.