DC Cable Connections 
 
Breaker Size 
Minimum Wire Size  14 AWG 
______________________________________________________________
CAUTION 
Loose connections cause excessive voltage drop and may cause overheated wires 
___________ _________________________________________________
CAUTION 
Do not over‐tighten the nut on the DC input terminals. Damage to the DC input 
terminals may result. The maximum torque setting is 10 ft‐lb (13.6 N‐m). 
        CAUTION: Reverse Polarity 
DC power connections to the Mobile Digital Power Inverter must be positive to 
positive and negative to negative. 
A reverse polarity connection (positive to negative) will blow fuses in the inverter 
and may permanently damage the inverter. The fuses are not user replaceable and 
the inverter may need to be returned for servicing. 
Damage caused by a reverse polarity connection is not covered by your warranty. 
 
 
 
 
 
 
 
 
 
 
 
 
 
10 A 
15 A 
14 AWG 
and melted insulation. 
20 A 
30 A 
12 AWG
10 AWG