  • Page 2 Important Safety Introductions  IMPORTANT:Read and keep this Owner’s Manual for future reference.  This chapter contains important safety and operating instructions.      WARNING:Limitations on use  The Mobile Digital Power Inverter is not intended for use in connection with life  support systems of other medical equipment of devices.          1. Before installing and using the Mobile Digital Power Inverter, read all  instructions and cautionary markings on the Mobile Digital Power Inverter, the  batteries, and all appropriate sections of this guide.  2. Do not expose the Mobile Digital Power Inverter to rain, snow, spray, or bilge  water. To reduce risk of fire hazard, do not cover or obstruct the ventilation  openings. Do not install the Mobile Digital Power Inverter in a zero‐clearance  compartment. Overheating may result.  3. Use only attachments recommended or sold by the manufacturer. Doing  otherwise may result in a risk of fire, electric shock, or injury to persons.  4. To avoid a risk of fire and electric shock, make sure that existing wiring is in  good condition and that wire is not undersized. Do not operate the Mobile Digital  Power Inverter with damaged or substandard wiring.  5. Do not operate the Mobile Digital Power Inverter if it has received a sharp blow,  been dropped, or otherwise damaged in any way. If the Mobile Digital Power  Inverter is damaged, see the Warranty section.  6. Do not disassemble the Mobile Digital Power Inverter. It contains no  user‐serviceable parts. See Warranty section for instructions on obtaining service.  Attempting to service the Mobile Digital Power Inverter yourself may result in a risk  of electrical shock or fire. Internal capacitors remain charged after all power is  disconnected.  7. To reduce the risk of electrical shock, disconnect both AC and DC power from  the Mobile Digital Power Inverter before attempting any maintenance or cleaning or  working on any circuits connected to the Mobile Digital Power Inverter. Turning off  controls will not reduce this risk.           ...
  • Page 3 Precautions for Working with Batteries        WARNING: Explosion hazard        1. Follow all instructions published by the battery manufacturer and the  manufacturer of the equipment in which the battery is installed.    2. Make sure the area around the battery is well ventilated.    3. Never smoke or allow a spark or flame near the engine or batteries.    4. Use caution to reduce the risk of dropping a metal tool on the battery.    It could spark or short circuit the battery or other electrical parts and could cause an  explosion.    5. Remove all metal items, like rings, bracelets, and watches when working with  lead‐acid batteries. Lead‐acid batteries produce a short circuit current high enough  to weld metal to skin, causing a severe burn.    6. Have someone within the range of your voice or close enough to come to  your aid when you work near a lead‐acid battery.    7. Have plenty of fresh water and soap nearby in case battery acid contacts skin,  clothing, or eyes.    8. Wear complete eye protection and clothing protection. Avoid touching your  eyes while working near batteries.    9. If battery acid contacts skin or clothing, wash immediately with soap and  water. If acid enters your eye, immediately flood it with running cold water for at  least twenty minutes and get medical attention immediately.    10. If you need to remove a battery, make sure all accessories are off so you  don’t cause a spark.     ...
  • Page 4 Precautions for Using Rechargeable Appliance        CAUTION:Equipment damage      The output of the inverter is non‐sinusoidal.      Most rechargeable battery‐operated equipment uses a separate charger or    transformer that is plugged into an AC receptacle and produces a low    voltage charging output.  Some chargers for small rechargeable batteries can be damaged if    connected to the Mobile Digital Power Inverter. Do not use the following with the  Mobile Digital Power Inverter:  • Small battery‐operated appliances like flashlights, razors, and night    lights that can be plugged directly into an AC receptacle to recharge.  • Some chargers for battery packs used in power hand tools.    These affected chargers display a warning label stating that dangerous voltages are  present at the battery terminals.  If you are unsure about using your rechargeable appliance with the    Mobile Digital Power Inverter, contact the equipment manufacturer to determine  the rechargeable appliance’s compatibility with the modified sine wave  (non‐sinusoidal) AC waveform.      CAUTION:Equipment damage    Do not connect live AC power to the Mobile Digital Power Inverter’s AC outlets.The  inverter will be damaged even if it is switched OFF.  Do not connect any AC load that has its neutral conductor connected to the Mobile  Digital Power Inverter.     ...
  • Page 5: Table Of Contents

    Important Safety Instructions …………………………………………………………………. 1 Introduction …………………………………………………………..……………………….. Quality Power …………………………………………………………..………………………... Ease of Use …………………………………………………………………………..…………... Comprehensive Protection …………………………………………………………………….. 2 Features …………………………………………………………………………..…………….. Materials List …………………………………………………………………………..………… AC Panel …………………………………………………………………………..………………. DC Panel …………………………………………………………………………..………………. 3 Installation ……………………………………………………………………………………... Calculating Battery Requirements …………………………………………………………… Choosing an Appropriate Location ……………………………………………………………...
  • Page 6: Introduction

    1 Introduction    Congratulations on your purchase of the Mobile Digital Power Inverter! The  Mobile Digital Power Inverter has been designed to give you quality power, ease of  use, and reliability. Please take a few moments to read this chapter to familiarize  yourself with the main performance features and protection features of the Mobile  Digital Power Inverter.    Quality Power    The Mobile Digital Power Inverter is a quality inverter designed for recreational  vehicle (RV) and truck applications.  • The Mobile Digital Power Inverter provides up to 1500 W of continuous power.  It is designed to handle loads such as 600 W microwaves, TVs, VCRs, and midsized  power tools.  • The Mobile Digital Power Inverter’s high surge capability lets you handle many  hard‐to‐start loads, including large TVs and small refrigerators.  • When the Mobile Digital Power Inverter is on but no power is being supplied to  a load, the inverter will draw less than 2A.    Please turn the inverter off when not in  use to prevent unnecessary battery discharge.  • The remote control will function when the power switch on the Mobile Digital  Inverter is in the off position.    It will not function when the switch is turned on.    Make sure the remote control cable is connected to the inverter securely and the  switch is off before operating the remote control.  • The cooling fan will activate under two conditions.    1) When loads are attached to the inverter and draw a significant amount of power,  2)  When  the  internal  temperature  exceeds  the  inverters  ambient  operating  temperature. ...
  • Page 7: Comprehensive Protection

    Comprehensive Protection  The Mobile Digital Power Inverter is equipped with numerous protection features to  guarantee safe and trouble‐free operation:  Low battery alarm alerts you if the battery has become discharged to 10.5 V ‐ 11.5 V.    Low battery voltage shutdown shuts the Mobile Digital Power Inverter down  automatically if the battery voltage drops below 10.0 V ‐ 11.0 V.  This feature protects the battery from being completely discharged.  High battery voltage shutdown shuts the Mobile Digital Power Inverter down  automatically if the input voltage rises to 15 V ‐ 16.3 V.  Overload shutdown shuts the Mobile Digital Power Inverter down automatically if a  short circuit is detected in the circuitry connected to the inverter’s output, or if the  loads connected to the inverter exceed the inverter’s operating limits.  Over temperature shutdown shuts the Mobile Digital Power Inverter down  automatically if its internal temperature rises above an unacceptable level.                                                     ...
  • Page 8: Features

    2 Features  Chapter 2 describes the main features of the Mobile Digital Power Inverter.    We recommend that you familiarize yourself with them before installing and  operating the inverter.    Materials List  Your Mobile Digital Power Inverter package includes:  •    One Mobile Digital Power Inverter  •    One 1.8 m wired remote control    •    Owner’s Manual  If any of these materials are missing or are unsatisfactory in any way,    please contact our TOLL‐FREE HELPLINE: 1‐877‐466‐8191    AC Panel              Figure 2‐1 AC Panel    Feature    Description    ON/OFF switch turns the inverter’s control circuit on and off. This  1  switch is not a power disconnect switch. Disconnect AC and DC    power before working on any circuits connected to the inverter.   ...
  • Page 9: Dc Panel

    Ventilation Openings must not be obstructed for the proper operation of the inverter. When the inverter is mounted, the ventilation openings must not point up or down. LED Display: Show DC input voltage (V)/AC output voltage (V)/AC output power (KW) NOTE: If you use the 600 W output, AC output power will display 0.60;...
  • Page 10: Installation

    3 Installation  We highly recommend that you read the entire chapter before beginning the  installation procedures so that you can plan an installation that is suited to your  power needs.    Calculating Battery Requirements  Battery type and battery size strongly affect the performance of the Mobile Digital  Power Inverter. Therefore, you need to identify the type of loads your inverter will  be powering, and how much you will be using them between charges. Once you  know how much power you will be using, you can determine how much battery  capacity you need. We recommend that you purchase as much battery capacity as  possible.        CAUTION  The Mobile Digital Power Inverter must only be connect to a 12 V battery system.It  will not operate if connected to a 6 V battery, and will be damaged if connected  to a battery with 16 V or more.      Choosing an Apporiate Location        WARNING:Explosion or fire hazard  The Mobile Digital Power Inverter contains components that tend to produce  Arcs or sparks.To prevent fire or explosion,do not install the inverter in  compartments containing batteries or flammable materials,or in locations  that require ignition‐protected equipment .        WARNING:Fire hazard  To reduce the risk of fire,do not cover or obstruct the ventilation Openings.Do not  install the Mobile power Inverter in a zero‐clearance compartment.Overheating may  result.         ...
  • Page 11: Calculating Cable Sizes

    The Mobile Digital Power Inverter must only be installed in a location that is:  Dry                          Do not allow water or other liquids to drop or splash on it.    Cool                      Ambient air temperature should be between 32 °F and 105 °F (0°C  and 40°C)—the cooler the better within this range.    Ventilated            Allow at least 3”(7.5cm) of clearance around the inverter for air  flow.Ensure that the ventilated openings on the DC end and on the  AC end of the unit are not obstructed.    Safe ...
  • Page 12: Dc Panel Connections

    3.  Attach  the  connectors  that  will  secure  the  cables  to  the  battery,  to  the  disconnect/battery  selector  switch,  and  the  fuse  block.  The  connectors  you  use  must  create  a  permanent,  low‐resistance  connection.  If  crimp  connectors  are  required, MotoMaster recommends using approved and certified connectors, and  to use the tool recommended by the terminal manufacturer. Make sure no stray  wires protrude from the connector or terminal.    4.  For  each  cable  end  that  will  be  connected  to  the  inverter,  strip  1/2"(13  mm)  to ...
  • Page 13: Dc Cable Connections

      DC Cable Connections    Breaker Size  10 A  15 A  20 A  30 A  Minimum Wire Size  14 AWG  14 AWG  12 AWG 10 AWG ______________________________________________________________ CAUTION  Loose connections cause excessive voltage drop and may cause overheated wires  and melted insulation.  ___________ _________________________________________________ CAUTION  Do not over‐tighten the nut on the DC input terminals. Damage to the DC input  terminals may result. The maximum torque setting is 10 ft‐lb (13.6 N‐m).          CAUTION: Reverse Polarity  DC power connections to the Mobile Digital Power Inverter must be positive to  positive and negative to negative.  A reverse polarity connection (positive to negative) will blow fuses in the inverter  and may permanently damage the inverter. The fuses are not user replaceable and  the inverter may need to be returned for servicing.  Damage caused by a reverse polarity connection is not covered by your warranty.                 ...
  • Page 14: Operation

    4 Operation  Chapter 4 explains how to operate the Mobile Digital Power Inverter efficiently and  effectively. Specifically, this chapter:  • Gives procedures for operating the inverter from the front panel        • Discusses operating limits and inverter loads      • Provides information about routine maintenance  Turning the Inverter ON and OFF  The ON/OFF switch on the inverter’s front panel turns the control circuit in the  Mobile Digital Power Inverter on and off.  To turn the inverter on and off from its front panel:  • Move the ON/OFF switch to the ON position to turn the inverter on.  • Move the ON/OFF switch to the OFF position to turn the inverter off.  When the switch is off, the inverter draws a very low current from the battery.  NOTE: The digital display on the inverter may not show the exact power in watts  that is being used.   Devices that draw a small load when compared to the capacity  of  the  inverter  may  display  zero  for  power  out,  this  is  normal.   Please  double  check  that  the  small  load  device  is  working  as  expected  if  the  display  shows  a  zero.  ...
  • Page 15: Turning The Inverter Off Between Uses

    Turning the Inverter Off Between Uses  The Mobile Digital Power Inverter draws less than 2 A from the battery with          the ON/OFF switch turned on and no load connected, but left in this state        the Mobile Digital Power Inverter will eventually discharge the battery.      To prevent unnecessary battery discharge, turn the Mobile Digital Power Inverter    off when you are not using it.    Operating Limits    Power Output  The Mobile Digital Power Inverter can deliver up to 1500 W continuous.    The wattage rating applies to resistive loads such as incandescent lights.    Input Voltage                                          The allowable Mobile Digital Power Inverter input voltage ranges are shown in the ...
  • Page 16: Trouble Loads

    overload shutdown circuit. This shutdown is intermittent. It will automatically restart,  then  shutdown  like  a  flashlight.  We  recommend  you  to  check  the  output  of  your  appliance.      Trouble Loads          CAUTION  Some equipment may be damaged by the Mobile Digital Power Inverter’s modified  sine wave output.                Some appliances, including the types listed below, may be damaged if they are  connected to the Mobile Digital Power Inverter:  • Electronics that modulate RF (radio frequency) signals on the AC line  will not work and may be damaged.  • Speed controllers found in some fans, power tools, kitchen appliances, and  other loads may be damaged.  • Some chargers for small rechargeable batteries can be damaged. See  “Precautions for Using Rechargeable Appliances” for details. ...
  • Page 17: Troubleshooting

    5 Troubleshooting  Chapter 5 will help you identify the source of most problems that can occur with the  Mobile Digital Power Inverter.  If you have a problem with the inverter, please review this chapter before contacting  your dealer.    Buzz in Audio Equipment  Some inexpensive stereo systems may emit a buzzing noise from their loudspeakers  when operated from the Mobile Digital Power Inverter. This occurs because the  power supply in the audio system does not adequately filter the modified sine wave  produced by the inverter. The only solution is to use a sound system that has a  higher quality power supply.    Television Reception  When the Mobile Digital Power Inverter is operating, it can interfere with  television reception on some channels. If interference occurs, try the following:  1. Make sure that the television antenna provides an adequate (“snow‐  free”) signal, and that you are using good quality cable between the antenna and the  television.  2. Keep the cables between the battery and the Mobile Digital Power Inverter  as short as possible, and twist them together with two to three twists per foot. (This  minimizes radiated interference from the cables.)  3. Move the television as far away from the Mobile Digital Power Inverter as  possible.  4. Do not operate high power loads with the Mobile Digital Power Inverter while  the television is on.    Troubleshooting Reference      WARNING: Electrical Shock and Burn Hazard  Do not disassemble the Mobile Digital Power Inverter. It does not contain any user  serviceable parts. Attempting to service the unit yourself could result in an electrical  shock or burn.                     ...
  • Page 18 Table 5‐1 Troubleshooting Reference  Problem  Possible Cause  Solution  Low output  You are using a voltmeter  Use a true RMS reading voltmeter.  voltage  that cannot accurately read  Check the connections and cable to  (96 V AC–104  the RMS voltage of a  see if the battery is fully charged.  V AC)  modified sine wave. Low  Recharge the battery if it is low.  input voltage and the load is  Reduce the load.  close to maximum allowable  power.  No output  The inverter is off.  Turn the inverter on.  voltage  No power to the inverter.  Check the wiring to the inverter and  Both the  The inverter could have  to the Disconnect/Battery Selector  Power light  been connected with reverse  switch.  and Fault  DC input polarity.  The inverter has probably been  light are off.  damaged. Return the unit. Damage  caused by reverse polarity is not  covered by the warranty. Information  for returning the inverter is provided  in the Warranty section ...
  • Page 19: A Specifications

    A Specifications    Appendix A contains electrical performance and physical specifications for the  Mobile Digital Power Inverter  Note:Specifications are subject to change without notice.                                            Electrical Performance    Electrical performance  Mobile Digital Power  Inverter  Output power at 77°F (25°C) ambient    temperature and 12 V DC input:    • Maximum continuous output power  1500 W  • Maximum surge power  3000 W  Output voltage  120 V AC RMS ...
  • Page 20: B Product And System Information

        1‐Year Limited Warranty                                    Appendix B contains the warranty for your inverter as well as instructions for  returning the product for servicing.  Appendix B also has a form where you can record information about your system on  page B‐3, in case you need to contact Customer Service.    Disclaimer   ® Unless specifically agreed to in writing, MotoMaster  Canada:    (a) Makes no warranty as to the accuracy, sufficiency, or suitability of any technical  or other information provided in its manuals or other documentation.  (b) Assumes no responsibility or liability for loss or damage, whether direct, indirect,  consequential or incidental, which might arise out of the use of such information.  The use of any such information will be entirely at the user’s risk.    Warranty    What does this warranty cover? This product is manufactured from parts and  components that are new or equivalent to new, in accordance with ...
  • Page 21: Information About Your System

        If you need to contact customer service, please record the following details before  calling. This information will help our representatives give you better service.  • Type of installation [e.g. RV, truck, vehicle] ___________________________  • Length of time inverter has been installed____________________________  • Battery/battery bank size ______________________________  • DC wiring size and length______________________________  • Appliances operating when problem occurred __________________________  • Description of problem    ______________________________  ________________________________________________________  ________________________________________________________                                Service Contact Information  TOLL‐FREE HELPLINE: 1‐877‐466‐8191                Imported by MotoMaster Canada Toronto, Canada M4S 2B8   ...