1500 w pure sine inverter, 3000 w pure sine inverter. (16 pages)
Summary of Contents for Motomaster ELIMINATOR 299-5299-0
Page 1
Mobile Digital Power Inverter 299-5299-0 Owner’s Manual TOLL-FREE HELPLINE: 1-877-466-8191...
Page 2
Important Safety Introductions IMPORTANT:Read and keep this Owner’s Manual for future reference. This chapter contains important safety and operating instructions. WARNING:Limitations on use The Mobile Digital Power Inverter is not intended for use in connection with life support systems of other medical equipment of devices. 1. Before installing and using the Mobile Digital Power Inverter, read all instructions and cautionary markings on the Mobile Digital Power Inverter, the batteries, and all appropriate sections of this guide. 2. Do not expose the Mobile Digital Power Inverter to rain, snow, spray, or bilge water. To reduce risk of fire hazard, do not cover or obstruct the ventilation openings. Do not install the Mobile Digital Power Inverter in a zero‐clearance compartment. Overheating may result. 3. Use only attachments recommended or sold by the manufacturer. Doing otherwise may result in a risk of fire, electric shock, or injury to persons. 4. To avoid a risk of fire and electric shock, make sure that existing wiring is in good condition and that wire is not undersized. Do not operate the Mobile Digital Power Inverter with damaged or substandard wiring. 5. Do not operate the Mobile Digital Power Inverter if it has received a sharp blow, been dropped, or otherwise damaged in any way. If the Mobile Digital Power Inverter is damaged, see the Warranty section. 6. Do not disassemble the Mobile Digital Power Inverter. It contains no user‐serviceable parts. See Warranty section for instructions on obtaining service. Attempting to service the Mobile Digital Power Inverter yourself may result in a risk of electrical shock or fire. Internal capacitors remain charged after all power is disconnected. 7. To reduce the risk of electrical shock, disconnect both AC and DC power from the Mobile Digital Power Inverter before attempting any maintenance or cleaning or working on any circuits connected to the Mobile Digital Power Inverter. Turning off controls will not reduce this risk. ...
Page 3
Precautions for Working with Batteries WARNING: Explosion hazard 1. Follow all instructions published by the battery manufacturer and the manufacturer of the equipment in which the battery is installed. 2. Make sure the area around the battery is well ventilated. 3. Never smoke or allow a spark or flame near the engine or batteries. 4. Use caution to reduce the risk of dropping a metal tool on the battery. It could spark or short circuit the battery or other electrical parts and could cause an explosion. 5. Remove all metal items, like rings, bracelets, and watches when working with lead‐acid batteries. Lead‐acid batteries produce a short circuit current high enough to weld metal to skin, causing a severe burn. 6. Have someone within the range of your voice or close enough to come to your aid when you work near a lead‐acid battery. 7. Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes. 8. Wear complete eye protection and clothing protection. Avoid touching your eyes while working near batteries. 9. If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters your eye, immediately flood it with running cold water for at least twenty minutes and get medical attention immediately. 10. If you need to remove a battery, make sure all accessories are off so you don’t cause a spark. ...
Page 4
Precautions for Using Rechargeable Appliance CAUTION:Equipment damage The output of the inverter is non‐sinusoidal. Most rechargeable battery‐operated equipment uses a separate charger or transformer that is plugged into an AC receptacle and produces a low voltage charging output. Some chargers for small rechargeable batteries can be damaged if connected to the Mobile Digital Power Inverter. Do not use the following with the Mobile Digital Power Inverter: • Small battery‐operated appliances like flashlights, razors, and night lights that can be plugged directly into an AC receptacle to recharge. • Some chargers for battery packs used in power hand tools. These affected chargers display a warning label stating that dangerous voltages are present at the battery terminals. If you are unsure about using your rechargeable appliance with the Mobile Digital Power Inverter, contact the equipment manufacturer to determine the rechargeable appliance’s compatibility with the modified sine wave (non‐sinusoidal) AC waveform. CAUTION:Equipment damage Do not connect live AC power to the Mobile Digital Power Inverter’s AC outlets.The inverter will be damaged even if it is switched OFF. Do not connect any AC load that has its neutral conductor connected to the Mobile Digital Power Inverter. ...
Important Safety Instructions …………………………………………………………………. 1 Introduction …………………………………………………………..……………………….. Quality Power …………………………………………………………..………………………... Ease of Use …………………………………………………………………………..…………... Comprehensive Protection …………………………………………………………………….. 2 Features …………………………………………………………………………..…………….. Materials List …………………………………………………………………………..………… AC Panel …………………………………………………………………………..………………. DC Panel …………………………………………………………………………..………………. 3 Installation ……………………………………………………………………………………... Calculating Battery Requirements …………………………………………………………… Choosing an Appropriate Location ……………………………………………………………...
1 Introduction Congratulations on your purchase of the Mobile Digital Power Inverter! The Mobile Digital Power Inverter has been designed to give you quality power, ease of use, and reliability. Please take a few moments to read this chapter to familiarize yourself with the main performance features and protection features of the Mobile Digital Power Inverter. Quality Power The Mobile Digital Power Inverter is a quality inverter designed for recreational vehicle (RV) and truck applications. • The Mobile Digital Power Inverter provides up to 1500 W of continuous power. It is designed to handle loads such as 600 W microwaves, TVs, VCRs, and midsized power tools. • The Mobile Digital Power Inverter’s high surge capability lets you handle many hard‐to‐start loads, including large TVs and small refrigerators. • When the Mobile Digital Power Inverter is on but no power is being supplied to a load, the inverter will draw less than 2A. Please turn the inverter off when not in use to prevent unnecessary battery discharge. • The remote control will function when the power switch on the Mobile Digital Inverter is in the off position. It will not function when the switch is turned on. Make sure the remote control cable is connected to the inverter securely and the switch is off before operating the remote control. • The cooling fan will activate under two conditions. 1) When loads are attached to the inverter and draw a significant amount of power, 2) When the internal temperature exceeds the inverters ambient operating temperature. ...
Comprehensive Protection The Mobile Digital Power Inverter is equipped with numerous protection features to guarantee safe and trouble‐free operation: Low battery alarm alerts you if the battery has become discharged to 10.5 V ‐ 11.5 V. Low battery voltage shutdown shuts the Mobile Digital Power Inverter down automatically if the battery voltage drops below 10.0 V ‐ 11.0 V. This feature protects the battery from being completely discharged. High battery voltage shutdown shuts the Mobile Digital Power Inverter down automatically if the input voltage rises to 15 V ‐ 16.3 V. Overload shutdown shuts the Mobile Digital Power Inverter down automatically if a short circuit is detected in the circuitry connected to the inverter’s output, or if the loads connected to the inverter exceed the inverter’s operating limits. Over temperature shutdown shuts the Mobile Digital Power Inverter down automatically if its internal temperature rises above an unacceptable level. ...
2 Features Chapter 2 describes the main features of the Mobile Digital Power Inverter. We recommend that you familiarize yourself with them before installing and operating the inverter. Materials List Your Mobile Digital Power Inverter package includes: • One Mobile Digital Power Inverter • One 1.8 m wired remote control • Owner’s Manual If any of these materials are missing or are unsatisfactory in any way, please contact our TOLL‐FREE HELPLINE: 1‐877‐466‐8191 AC Panel Figure 2‐1 AC Panel Feature Description ON/OFF switch turns the inverter’s control circuit on and off. This 1 switch is not a power disconnect switch. Disconnect AC and DC power before working on any circuits connected to the inverter. ...
Ventilation Openings must not be obstructed for the proper operation of the inverter. When the inverter is mounted, the ventilation openings must not point up or down. LED Display: Show DC input voltage (V)/AC output voltage (V)/AC output power (KW) NOTE: If you use the 600 W output, AC output power will display 0.60;...
3 Installation We highly recommend that you read the entire chapter before beginning the installation procedures so that you can plan an installation that is suited to your power needs. Calculating Battery Requirements Battery type and battery size strongly affect the performance of the Mobile Digital Power Inverter. Therefore, you need to identify the type of loads your inverter will be powering, and how much you will be using them between charges. Once you know how much power you will be using, you can determine how much battery capacity you need. We recommend that you purchase as much battery capacity as possible. CAUTION The Mobile Digital Power Inverter must only be connect to a 12 V battery system.It will not operate if connected to a 6 V battery, and will be damaged if connected to a battery with 16 V or more. Choosing an Apporiate Location WARNING:Explosion or fire hazard The Mobile Digital Power Inverter contains components that tend to produce Arcs or sparks.To prevent fire or explosion,do not install the inverter in compartments containing batteries or flammable materials,or in locations that require ignition‐protected equipment . WARNING:Fire hazard To reduce the risk of fire,do not cover or obstruct the ventilation Openings.Do not install the Mobile power Inverter in a zero‐clearance compartment.Overheating may result. ...
The Mobile Digital Power Inverter must only be installed in a location that is: Dry Do not allow water or other liquids to drop or splash on it. Cool Ambient air temperature should be between 32 °F and 105 °F (0°C and 40°C)—the cooler the better within this range. Ventilated Allow at least 3”(7.5cm) of clearance around the inverter for air flow.Ensure that the ventilated openings on the DC end and on the AC end of the unit are not obstructed. Safe ...
3. Attach the connectors that will secure the cables to the battery, to the disconnect/battery selector switch, and the fuse block. The connectors you use must create a permanent, low‐resistance connection. If crimp connectors are required, MotoMaster recommends using approved and certified connectors, and to use the tool recommended by the terminal manufacturer. Make sure no stray wires protrude from the connector or terminal. 4. For each cable end that will be connected to the inverter, strip 1/2"(13 mm) to ...
DC Cable Connections Breaker Size 10 A 15 A 20 A 30 A Minimum Wire Size 14 AWG 14 AWG 12 AWG 10 AWG ______________________________________________________________ CAUTION Loose connections cause excessive voltage drop and may cause overheated wires and melted insulation. ___________ _________________________________________________ CAUTION Do not over‐tighten the nut on the DC input terminals. Damage to the DC input terminals may result. The maximum torque setting is 10 ft‐lb (13.6 N‐m). CAUTION: Reverse Polarity DC power connections to the Mobile Digital Power Inverter must be positive to positive and negative to negative. A reverse polarity connection (positive to negative) will blow fuses in the inverter and may permanently damage the inverter. The fuses are not user replaceable and the inverter may need to be returned for servicing. Damage caused by a reverse polarity connection is not covered by your warranty. ...
4 Operation Chapter 4 explains how to operate the Mobile Digital Power Inverter efficiently and effectively. Specifically, this chapter: • Gives procedures for operating the inverter from the front panel • Discusses operating limits and inverter loads • Provides information about routine maintenance Turning the Inverter ON and OFF The ON/OFF switch on the inverter’s front panel turns the control circuit in the Mobile Digital Power Inverter on and off. To turn the inverter on and off from its front panel: • Move the ON/OFF switch to the ON position to turn the inverter on. • Move the ON/OFF switch to the OFF position to turn the inverter off. When the switch is off, the inverter draws a very low current from the battery. NOTE: The digital display on the inverter may not show the exact power in watts that is being used. Devices that draw a small load when compared to the capacity of the inverter may display zero for power out, this is normal. Please double check that the small load device is working as expected if the display shows a zero. ...
Turning the Inverter Off Between Uses The Mobile Digital Power Inverter draws less than 2 A from the battery with the ON/OFF switch turned on and no load connected, but left in this state the Mobile Digital Power Inverter will eventually discharge the battery. To prevent unnecessary battery discharge, turn the Mobile Digital Power Inverter off when you are not using it. Operating Limits Power Output The Mobile Digital Power Inverter can deliver up to 1500 W continuous. The wattage rating applies to resistive loads such as incandescent lights. Input Voltage The allowable Mobile Digital Power Inverter input voltage ranges are shown in the ...
overload shutdown circuit. This shutdown is intermittent. It will automatically restart, then shutdown like a flashlight. We recommend you to check the output of your appliance. Trouble Loads CAUTION Some equipment may be damaged by the Mobile Digital Power Inverter’s modified sine wave output. Some appliances, including the types listed below, may be damaged if they are connected to the Mobile Digital Power Inverter: • Electronics that modulate RF (radio frequency) signals on the AC line will not work and may be damaged. • Speed controllers found in some fans, power tools, kitchen appliances, and other loads may be damaged. • Some chargers for small rechargeable batteries can be damaged. See “Precautions for Using Rechargeable Appliances” for details. ...
5 Troubleshooting Chapter 5 will help you identify the source of most problems that can occur with the Mobile Digital Power Inverter. If you have a problem with the inverter, please review this chapter before contacting your dealer. Buzz in Audio Equipment Some inexpensive stereo systems may emit a buzzing noise from their loudspeakers when operated from the Mobile Digital Power Inverter. This occurs because the power supply in the audio system does not adequately filter the modified sine wave produced by the inverter. The only solution is to use a sound system that has a higher quality power supply. Television Reception When the Mobile Digital Power Inverter is operating, it can interfere with television reception on some channels. If interference occurs, try the following: 1. Make sure that the television antenna provides an adequate (“snow‐ free”) signal, and that you are using good quality cable between the antenna and the television. 2. Keep the cables between the battery and the Mobile Digital Power Inverter as short as possible, and twist them together with two to three twists per foot. (This minimizes radiated interference from the cables.) 3. Move the television as far away from the Mobile Digital Power Inverter as possible. 4. Do not operate high power loads with the Mobile Digital Power Inverter while the television is on. Troubleshooting Reference WARNING: Electrical Shock and Burn Hazard Do not disassemble the Mobile Digital Power Inverter. It does not contain any user serviceable parts. Attempting to service the unit yourself could result in an electrical shock or burn. ...
Page 18
Table 5‐1 Troubleshooting Reference Problem Possible Cause Solution Low output You are using a voltmeter Use a true RMS reading voltmeter. voltage that cannot accurately read Check the connections and cable to (96 V AC–104 the RMS voltage of a see if the battery is fully charged. V AC) modified sine wave. Low Recharge the battery if it is low. input voltage and the load is Reduce the load. close to maximum allowable power. No output The inverter is off. Turn the inverter on. voltage No power to the inverter. Check the wiring to the inverter and Both the The inverter could have to the Disconnect/Battery Selector Power light been connected with reverse switch. and Fault DC input polarity. The inverter has probably been light are off. damaged. Return the unit. Damage caused by reverse polarity is not covered by the warranty. Information for returning the inverter is provided in the Warranty section ...
A Specifications Appendix A contains electrical performance and physical specifications for the Mobile Digital Power Inverter Note:Specifications are subject to change without notice. Electrical Performance Electrical performance Mobile Digital Power Inverter Output power at 77°F (25°C) ambient temperature and 12 V DC input: • Maximum continuous output power 1500 W • Maximum surge power 3000 W Output voltage 120 V AC RMS ...
1‐Year Limited Warranty Appendix B contains the warranty for your inverter as well as instructions for returning the product for servicing. Appendix B also has a form where you can record information about your system on page B‐3, in case you need to contact Customer Service. Disclaimer ® Unless specifically agreed to in writing, MotoMaster Canada: (a) Makes no warranty as to the accuracy, sufficiency, or suitability of any technical or other information provided in its manuals or other documentation. (b) Assumes no responsibility or liability for loss or damage, whether direct, indirect, consequential or incidental, which might arise out of the use of such information. The use of any such information will be entirely at the user’s risk. Warranty What does this warranty cover? This product is manufactured from parts and components that are new or equivalent to new, in accordance with ...
If you need to contact customer service, please record the following details before calling. This information will help our representatives give you better service. • Type of installation [e.g. RV, truck, vehicle] ___________________________ • Length of time inverter has been installed____________________________ • Battery/battery bank size ______________________________ • DC wiring size and length______________________________ • Appliances operating when problem occurred __________________________ • Description of problem ______________________________ ________________________________________________________ ________________________________________________________ Service Contact Information TOLL‐FREE HELPLINE: 1‐877‐466‐8191 Imported by MotoMaster Canada Toronto, Canada M4S 2B8 ...