Table 3‐1 Recommended DC Input Wire Size & Lengths 
 
Cable length: Battery 
to inverter(one way) 
Less than 5'(1.5m) 
 
Note: Never use a DC cable longer than 5' (1.5 m) with the Mobile Digital Power 
Inverter.    Appropriately sized cable can be bought at a welding supply house or a 
marine supply store. 
 
DC Panel Connections 
This item not include DC cable 
 
A.Connect black cable with negative pole of battery (A: black), connect another side 
with negative pole of inverter (A: black) 
B.  Connect red cable with positive pole of battery (B: red), connect another side 
with positive pole of inverter (B: red) 
Note: Do not connect with wrong side, otherwise inverter may damage. 
1. Make sure the inverter is off and no AC or DC is connected to the unit. 
2. Remove the nuts and washers from the positive and negative DC terminals. 
3.  Attach  the  connectors  that  will  secure  the  cables  to  the  battery,  to  the 
disconnect/battery  selector  switch,  and  the  fuse  block.  The  connectors  you  use 
must  create  a  permanent,  low‐resistance  connection.  If  crimp  connectors  are 
required, MotoMaster recommends using approved and certified connectors, and 
to use the tool recommended by the terminal manufacturer. Make sure no stray 
wires protrude from the connector or terminal.   
4.  For  each  cable  end  that  will  be  connected  to  the  inverter,  strip  1/2"(13  mm)  to 
3/4" (19 mm) of insulation from the cable. The amount stripped off will depend on 
the terminals chosen. 
Noted: This item not include DC cable 
5. Thread a DC terminal cover over the positive and negative cables. The red cover 
goes on the positive cable; the black cover on the negative cable. 
6. To prevent sparking when making the connection, ensure the disconnect/battery 
selector switch is off. 
7. Install the lock washer and nut that are supplied with the inverter. Tighten the nut 
to a torque of 9–10 ft‐lb (12.2–13.6 N‐m). Make the connection snug enough so 
the  ring  terminal  does  not  move  around  on  the  DC  terminal,  but  do  not  over 
tighten.   
 
 
a
RV
(Recreational Vehicle) 
Minimum Cable Size 
No. 2 AWG 
7
Minimum Battery Fuse Size
150 A DC 