FireAngel Thermoptek ST-620 User Manual

FireAngel Thermoptek ST-620 User Manual

Hide thumbs Also See for Thermoptek ST-620:

Advertisement

User Manual
SMOKE ALARM
10 YEAR LIFE
ST-620
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Thermoptek ST-620 and is the answer not in the manual?

Questions and answers

Mrs P Shuttleworth
July 1, 2025

My Fireangel smoke alarm was changed but the old one still beeps on a test and flashes. How do I deactivate it so I can dispose of it.

Summary of Contents for FireAngel Thermoptek ST-620

  • Page 1 User Manual SMOKE ALARM 10 YEAR LIFE ST-620...
  • Page 2 0086 EN 14604:2005 0086-CPR-557790 KM 557789 Smoke alarm devices EN 14604:2005 DOP: SADOPST-620-03 ST-620 GN0681R5 A Sprue Safety Products Brand Sprue Safety Products Ltd. Vanguard Centre, Sir William Lyons Road, Coventry CV4 7EZ UK Technical Support: 0800 141 2561 EIRE dial: 1-800 523171 Email: technicalsupport@sprue.com Web: www.fireangel.co.uk...
  • Page 3: Table Of Contents

    CONTENTS Introduction ..4 Operation ... 7 Automatic Power Engage . . 4 Alarm Test ... 8 Thermoptek Sensor Alarm Smart Silence™...
  • Page 4: Introduction

    INTRODUCTION typical response time to fast flaming fires significantly. IMPORTANT: This user manual contains Thermoptek alarms “toast-proof” important information regarding meaning they can be positioned in area operation of your smoke alarm. Ensure you close to kitchens that may be affected by read this user manual fully before installing cooking fumes.
  • Page 5 WARNING: The alarm positions shown Multi-family mixed occupant below based typical homes. residence (Tenancy building, student Construction and layout of individual accommodation) dwellings will vary, so this should be Your smoke alarm can also be used in regarded only as a guide. Check with your individual flats and bedsits, providing the local fire station for further guidance.
  • Page 6: How To Install Your Smoke Alarm

    Commercial and Industrial Premises holes and insert the plastic fixing anchors This smoke alarm is not intended for any supplied (if needed). non-residential, commercial or industrial Install Base Plate application, nor for any other purpose than described above. Fit the base plate to the ceiling or wall using the screws provided.
  • Page 7: Operation

    OPERATION There are three lugs (hooks) on the back of the alarm that slide in to three slots on the base plate. The alarm can be attached in any Normal condition orientation, simply line up the lugs (hooks) The red LED on the front should flash every with the holes at the end of the slots then 40 seconds to show that the alarm is active.
  • Page 8: Alarm Test

    ALARM TEST The alarm must be properly attached to the base plate before it can be tested. a Press the test button in the centre and release. NOTE: The test button accurately tests the alarm’s smoke sensing circuit, there is no need to test your alarm with smoke.
  • Page 9 In the event of a known false alarm your c During the reduced sensitivity reset cycle, smoke alarm can be temporarily silenced by the red LED on your alarm will continue to flash more rapidly than normal, pressing the central test button. Your alarm approximately once every second.
  • Page 10: Troubleshooting

    TROUBLESHOOTING Problem Solution • Make sure the alarm has been rotated clockwise as far as it can go and is securely located on base plate (this means the power pack has been activated). If testing immediately after first activating the alarm you should allow a few seconds for the alarm to settle before Your smoke alarm testing.
  • Page 11: Maintenance

    MAINTENANCE IMPORTANT: Do not use solvents or cleaners on your smoke alarm, as they may Your smoke alarm has been designed to be cause damage to the sensor or circuitry. The as maintenance-free as possible, however unit can be wiped with a slightly damp cloth. there are several things you must do to keep CAUTION: Do not paint the smoke alarm it working properly.
  • Page 12: Disposal

    DISPOSAL accordance with the user manual. It does not cover events and conditions outside of Sprue Safety Products Ltd’s control, such as Acts of God (fire, severe weather Waste electrical products should not be disposed of etc.). It does not apply to retail stores, service centres with your other household waste.