11.5 - Error code examples
Error
No communication between function selector and equipment. The incorrect or absence of connection of the func-
E00
tion selector causes the appearance of the error E 00 on the display of the PRO selector and non-operation of the
E101
E201
E102
E202
E03
E04
E05
Learned stroke greater than the maximum permitted. The equipment will only attempt to resume operation after be-
E06
E07
Motor polarity reversed or encoder channels reversed. The equipment stops and will only attempt to resume opera-
E08
Weight detected higher than the max. permissible. The equipment will only attempt to resume operation after being
E09
E10
Overload protection of the power circuit has occurred. The equipment will attempt to resume operation after a new
E11
E12
E13
E14
E15
E16
E17
E18
Excessive temperature of the power electronics. The equipment will only attempt to resume operation after being
E19
E20
34
P1
ESC
Obstacle detected with closing current. The equipment continues normal operation.
Obstacle detected due to encoder stopped during closure. The equipment continues normal operation.
Obstacle detected with opening current. The equipment continues normal operation.
Obstacle detected with encoder stopped in opening. The equipment continues normal operation.
Faulty encoder. The equipment stops and will only attempt to resume operation after being reset or turned off.
Power supply absent. The equipment continues operation, as set with parameter F.
Low battery. The equipment normally continues operation as long as the battery voltage permits it.
Motor current greater than the maximum permissible detected.
The equipment will attempt to resume operation after a new command.
EEPROM memory read or write error The equipment will attempt to resume operation only after being reset or
Monitored device test 1 failed PHOTO RALL command
Monitored device test 2 failed FOTO RALL command
Power electronics failure, The equipment will only attempt to resume operation after being reset or turned off.
PROGRAM MENÙ
P1
P5
P4
P2
ESC
OK
MENU
AS
Description
equipment display
ing reset or turned off.
Flat battery. The equipment stops.
tion after being reset or turned off.
reset or turned off.
command.
turned off.
Monitored device test 1 failed PHOTO command
Monitored device test 2 failed PHOTO command
Monitored device test 1 failed STOP command
Monitored device test 2 failed STOP command
reset or turned off.