Download Print this page

Advertisement

Quick Links

SPLIT TYPE ROOM
OPERATION M ANUAL
AS0 9 DCBHRA
AS12DCBHRA
AS18 DDBHRA
Please read this operation manual before using the air conditioner.
K eep this operation manual for future reference.
This appliance is filled with R3 2.
0 0 1150 0 24 7
AIR CONDITION
ER
AS26 DCBHRA
AS3 5DCBHRA
AS53 DDBHRA

Advertisement

loading

Summary of Contents for Haier AS09DCBHRA

  • Page 1 SPLIT TYPE ROOM AIR CONDITION OPERATION M ANUAL AS0 9 DCBHRA AS26 DCBHRA AS12DCBHRA AS3 5DCBHRA AS18 DDBHRA AS53 DDBHRA Please read this operation manual before using the air conditioner. K eep this operation manual for future reference. This appliance is filled with R3 2. 0 0 1150 0 24 7...
  • Page 2 Re a d t h e p r e c a u t i o n s i n t h i s m a n u a l Th i s a p p l i a n c e i s f i l l e d w i t h R3 2. c a r e f u l l y b e f o r e o p e r a t i n g t h e u n i t .
  • Page 3: Table Of Contents

    Contents PARTS AND FUNCTIONS OPERATION INDOOR UNIT INSTALLAION MAINTENANCE CAUTIONS TROUBLE SHOOTING...
  • Page 4: Parts And Functions

    Parts and Functions Indoor Unit Rem ote c ontrol l er Display board Inlet O u t e r s i d e o f t h e c o n t r o l l e r ( inside) ON / OFF button Inlet grille ON/OFF...
  • Page 5: Operation

    Operation 18 . TIM ER button Cl oc k s et 19 . CLOCK button 20 . 10 ºC button Press CLOCK button, special heating set function: 10 degree heating maintaining ( valuable for RS) 21. HEALTH button Press “ ”...
  • Page 6 Operation Operation COOL,HEAT and DRY Operation QUIET/TURBO Operation Unit start. Select operation mode. Press the COOL button on the remote control. QUIET/ QUIET/ QUIET/ TURBO TURBO TURBO QUIET/TURBO Operation SELF SELF CLEAN CLEAN ECOPILOT ECOPILOT QUIET QUIET Press the HEAT button on the remote control. You can use this function when silence is needed for rest or reading.
  • Page 7 Operation button. pressed, temp. setting increases 0 .5 ºC. pressed, temp. setting decreases 0 .5 ºC. QUIET/ QUIET/ TURBO TURBO Unit will start running to reach the CO ILO SELF SELF CLEAN CLEAN temp. setting on LCD. CO ILO CO ILO AN Operation changes as follows: cancel...
  • Page 8 Operation ECOP ILOT Operation HEALTH AIRF LOW Operation Human Sensing Function 1. “ Follow” function: It can detect where a person is and The setting of adjust the swing flap accordingly and send air to the location of this person. If it detects people in two function locations, the swing flap will blow alternatively between these two locations and stay at each location for 15s.
  • Page 9 Operation TIM ER Operation S W IN G Operation Set Clock correctly before starting Timer operation. You can let unit start or stop automatically a following times: Before you wake up in the morning, or get back from work or after you fall asleep at night.
  • Page 10 Operation Com f ortab l e S LEEP 3 hours before it stops. The temperature is lower than setting temperature so that it won’ t be too high for your Before going to bed, you can simply press the SLEEP sleep;...
  • Page 11 Operation S M ART Operation S ELF CLEAN Operation ( This function is unavailable on ◆Functional description: the purpose of this function is to clean the evaporator. some models) Entry and exit Press self clean button to enter this One key can give you a function, then it will display "...
  • Page 12 Operation HEALTH Operation ON /OF F operation and tes t operation ON/OFF Operation: The water- ion generator in the Use this operation only emergency running, for example, airconditioner can generate anion, when the remote controller is defective or lost. The air conditoner can run automatically for a while.
  • Page 13 K yoto Protocol ( This function is unavailable on some models.) R3 2 Haier Peaksmart enabled air- conditioners have a Demand Response M ode display on the indoor unit. The display could be labelled d1, d2, d3 ( wording may 1+2= differ model to model) .
  • Page 14: Indoor Unit Installaion

    Installation M anual of Room Air Conditioner Preparation Selection of Installation Place Necessary Tools for Installation Torq ue wrench Indoor Unit Driver ( 17 mm,22mm,26 mm) Nipper Place, with minimize shock and vibration, where the body can be supported suf ciently. Hacksaw Pipe cutter Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the...
  • Page 15 Indoor Unit Installation [ Left Left- rear piping ] Fitting of the M ounting Plate and Positioning of the wall Hole In case of left side piping, cut away, with a nipper, the lid for left piping. In case of left- rear piping, bend the pipes according to the piping When the mounting plate is first fixed direction to the mark of hole for left- rear piping which is marked on heat insulation materials.
  • Page 16 When connecting the cable after installing the indoor unit 1. Insert from outside the room cable into left side of the wall Damage of flare Lean Partial Too outside Crack hole, in which the pipe has already existed. 2. Pull out the cable on the front side, and connect the cable On Drainage making a loop.
  • Page 17: Maintenance

    Maintenance For Smart Use of The Air Conditioner Remote Controller Indoor Body Setting of proper room Do not block the air inlet temperature or outlet wipe the air conditioner by using a Proper temperature soft and dry cloth.For serious stains, use a neutral detergent diluted with Do not usewater,wipe the controller water.Wring the water out of the...
  • Page 18: Cautions

    Cautions WARNING Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. WARNING Check proper When abnormality such as burnt-small found, Use an exclusive immediately stop the operation button and power source installation of the...
  • Page 19: Trouble Shooting

    Trouble shooting Cautions Before asking for service, check the following Do not obstruct or cover the ventilation grille of the air first. conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver. This appliance is not intended for use by persons (including children) Phenomenon Cause or check points with reduced physiced, sensory or mental capabilities or lack of...
  • Page 20 You should therefore check with your dealer or Haier’s Customer Care Centre to ensure this fl yer correctly describes the products currently available. Fisher & Paykel Australia Pty Ltd, Level 1, 1 Eden Park Drive, Macquarie Park, NSW 2113.

This manual is also suitable for:

As12dcbhraAs18ddbhraAs26dcbhraAs35dcbhraAs53ddbhra