Installation M anual of Room Air Conditioner
Preparation
Necessary Tools for Installation
Driver
Nipper
Hacksaw
Hole core drill
Spanner( 17 ,19 and 26 mm)
G as leakage detector or
soap- and- water solution
Power Source
Before inserting power plug into receptacle, check the voltage without fail.
The power source is the same as the corresponding name plate.
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable can be
reached. Do not extend the cable by cutting it.
Drawing for the installation of indoor and outdoor units
The models adopt HFC free refrigerant R3 2
more than 20 cm
more than
20 cm
Arrangement of piping
directions
Rear left
Left
Below
The marks from
A
in the gure are the
G
parts numbers.
The distance between
the indoor unit and the
oor should be more
than 1.8 m.
more than 6 0 cm
Please refer to the actual product purchased , the above picture is just for your reference.
Read this manual before installation
Explain suf ciently the operating means to the user according to this manual
13
Torq ue wrench
( 17 mm,22mm,26 mm)
Pipe cutter
Flaring tool
K nife
M easuring tape
Reamer
Rear
right
Right
more than 3 0 cm
more than 3 0 cm
to
Indoor Unit
Place, with minimize shock and vibration, where the body can be supported suf ciently.
Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the
unit are not disturbed.
Place, possible to drain easily, where piping can be connected with the outdoor unit.
Place, where cold air can be spread in a room entirely.
Place, nearby a power receptacle, with enough space around. ( Refer to drawings) .
With the distance 1 meter from the television, radio, wireless apparatuse and fluorescent
lamp and be left.
In the case of xing the remote controller on a wall, place where the indoor unit can
receive signals when the uorescent lamps in the room are lightened.
Outdoor Unit
With less rain or direct sunshine.
Place, which is on a strong stand , where vibration and noise are not increased.
Place, where discharged wind and noise do not cause a nuisance to the neighbors.
Place, where a distance marked
Attention must be paid to
the rising up of drain hose
G
more than 10 cm
F
A
C
D
more than6 0 cm
Selection of Installation Place
is available as illustrated in the above gure.
Accessory parts
No.
Accessory parts
1
Remote controller
2
R- 0 3 dry battery
3
M ounting plate
4
Drain hose
5
Steel nail, cement
6
4 X 25
Screw
Cover
7
Pipe supporting plate
8
Filter
9
Flare nut
10
11
DRED
12
Drain- elbow
13
Cushion
Note: Cooling only units don' t have
Drain- elbow
E
Necessary parts for piping
Non- adhesive tape
A
Adhesive tape
B
Saddle ( L.S) with screws
C
Connecting electric cable
D
for indoor and outdoor
E
Drain hose
F
Heating insulating material
Piping hole cover
G
Number
of
articles
1
2
1
1
6
4 X 50
4
Plastic cap
1
1
2
2
1
1
4

Advertisement

loading

This manual is also suitable for:

As12dcbhraAs18ddbhraAs26dcbhraAs35dcbhraAs53ddbhra