Summary of Contents for Gima TOBI MANUALE

  • Page 1 ASPIRATORE CHIRURGICO TOBI MANUALE TOBI MANUALE SUCTION ASPIRATOR ASPIRATEUR TOBI MANUEL CHIRURGISCHER ABSAUGER “TOBI MANUALE” ASPIRADOR QUIRÚRGICO “TOBI MANUALE” APARELHO DE SUCÇÃO CIRÚRGICO “TOBI MANUALE” 28220 0476 Gima S.p.A. Via Marconi, 1 - 20060 Gessate (MI) Italy gima@gimaitaly.com - export@gimaitaly.com www.gimaitaly.com...
  • Page 2: Important Safety Rules

    ENGLISH TOBI MANUALE SUCTION ASPIRATOR it’s a manual device to be used for the emergency field to be used for the aspiration of the body liquids (mucus or catarrh or blood). Easily movable and designed for a manual use. Thanks to this characteristics and to the rating that it has product is particularly suitable for a emergency use, on the thacheotomized patients, minor surgical applications and post - operative therapy at home.
  • Page 3: Accessories Supplies

    ENGLISH The technical specifications may change without notice Shelf life: maximum 5 years from the date of manufacture ACCESSORIES SUPPLIES • Complete aspiration jar 4000ml • Conical fitting • Transparent tubes set 6 mm x 10mm • Hydrophobic and antibacterial filter The filter is made of hydrophobic material and blocks the passage of liquids that come into contact with it.
  • Page 4 PERIODICAL MAINTENANCE CHECKS The TOBI MANUALE SUCTION ASPIRATOR does not need maintenance or lubrication. It is necessary to check functioning and instrument before every use. Unpack the instrument and always check integrity of plastic parts, they might have been damaged during previous use. Close the aspirator outlet with your finger.
  • Page 5 Keep in a cool, dry place Keep away from sunlight Manufacturer Date of manufacture Product code Lot number Medical Device complies Serial number with Directive 93/42/EEC Temperature limit Humidity limit GIMA WARRANTY TERMS The Gima 12-month standard B2B warranty applies.